7. Performing a functional test

With all minitimers it is recommended to check function and switching
times before mounting them. Proceed according to the sections 8. (MT-
1), 9. (MT-2) or 10. (MT-3), but connect a lamp to the outputs for the
devices for the test.
Set the trimm pot as follows:
MT-1: left stop (= shortest possible switching time)
MT-2: middle position (= middle time delay)
MT-3: right stop (= shortest possible delay time)
Connect the minitimer to the power supply and trigger a switching
operation.
Caution:
!
If a component gets too hot, disconnect the mini-timer and power
supply from the mains immediately. Possible short circuit! Check the
assembly!