Performing A Visual Check; Check List For Troubleshooting - tams elektronik 70-01045 Manual

Adapter for plux- and 21mtc-interface
Hide thumbs Also See for 70-01045:
Table of Contents

Advertisement

English

7.3. Performing a visual check

After having soldered the cables you should perform a visual check and
remedy defects.
Check if soldering joints closely adjoining are connected to each
other by accident. Risk of short circuit!
Check if you have assigned the connecting cables on the adapter
PCB properly to the connections of the decoder.
Caution:
!
Confusing the connections can cause damages at the deocder and/or
at the vehicle. For that reason you should be very attentive when
assigning the connections.

8. Check list for troubleshooting

Parts are getting too hot and/or start to smoke.
Disconnect the system from the mains immediately!
!
Possible cause: The connecting cables on the PCB are badly assigned
to the connections of the decoder or the vehicle. à Perform a visual
check ( à chapter 7) and remedy defects. Damage on the decoder
or the vehicle cannot be excluded.
Possible cause: The plug connector or the socket have been inserted
the wrong way. à Check the connections and remove the index pin
to avoid mistakes like these.
You cannot switch function outputs of the decoder.
Possible cause: The connecting cables have not been soldered
properly. à Check the soldering joints.