Connecting The Booster-Link; Check List For Troubleshooting - tams elektronik mfx 49-02105 Manual

Adapter for booster
Table of Contents

Advertisement

English

7. Connecting the Booster-Link

Required number of Booster-Links
For each external booster supplying the mfx
Booster-Link. In case one external booster supplies several booster
sections one Booster-Link is sufficient.
Performing the booster sectionings
Isolate the centre conductor at the sectioning between the booster
sections (if not already done). Please note: The outer conductors must
not be isolated.
Connections
Make the connections according to the connections diagram (fig. 3) and
the pin connections.

8. Check list for troubleshooting

Parts are getting too hot and/or start to smoke.
!
Switch off the digital system immediately !
Possible cause: one or more components are soldered incorrectly.
 In case you have mounted the module from a kit, perform a
visual check ( section 6.) and if necessary, remedy the faults.
Otherwise send in the module for repair.
®
The mfx
decoders in those sections supplied by external boosters.
Possible Cause: One or several connections of the Booster-Link
have been interrupted or mixed up.  Check the three Booster-
Link´s connections.
Possible Cause: The Booster-Link is damaged.  In case you have
mounted the module from a kit, perform a visual check ( section
6.) and if necessary, remedy the faults. Otherwise send in the
module for repair.
Page 28
central unit does not display the feedback data of the
Booster-Link
®
layout you need one

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx 49-02106Mfx 49-02107Mfx49-0210549-0210649-02107

Table of Contents