BEE Regulation
Testing Guidelines
Cooling Test Mode for Full Load (100%) and
Half Load (50%)
•
Turn on the main power supply to unit.
1) Mode
2) Temperature
3) Air Swing
Vertical Airflow
4) Air Swing
Horizontal Airflow
5) Fan speed
•
Open the Front Panel by lifting Intake Grille.
•
Follow the below Instructions.
Step a): Press and Hold the button on indoor unit.
Step b): Within 5 second, press once the Remote
Control
OFF, while holding the indoor unit button.
Step c): After hearing a beep sound from the Indoor
Unit, immediately release the (Auto OFF/ON)
button on Indoor Unit.
All this should be done within 5 seconds.
Note: Unit is charged with extra 60g refrigerant for installation purging purpose.
For all laboratory tests, 60g shall be released to follow the rated refrigerant amount mentioned in nameplate.