BEE Regulation

Testing Guidelines
Cooling Test Mode for Full Load (100%) and
Half Load (50%)
Turn on the main power supply to unit.
1) Mode
2) Temperature
3) Air Swing
Vertical Airflow
4) Air Swing
Horizontal Airflow
5) Fan speed
Open the Front Panel by lifting Intake Grille.
Follow the below Instructions.
Step a): Press and Hold the button on indoor unit.
Step b): Within 5 second, press once the Remote
Control
OFF, while holding the indoor unit button.
Step c): After hearing a beep sound from the Indoor
Unit, immediately release the (Auto OFF/ON)
button on Indoor Unit.
All this should be done within 5 seconds.
Note: Unit is charged with extra 60g refrigerant for installation purging purpose.
For all laboratory tests, 60g shall be released to follow the rated refrigerant amount mentioned in nameplate.
10
: Select 'COOL'
: a) 16 ºC for Full Load (100%)
: b) 17 ºC for Half Load (50%)
: Set vane position to 3rd step
from top
: Set vane position to be
straight
(For applicable Model)
: Maximum
button when display is showing
POWER
TIMER
nanoe-G
PURIFIER
SLEEP /
POWERFUL
(Indication for Full load)
THREE LEDs FROM BOTTOM
STARTS BLINKING
QUIET
CLEAN
1
2
1
2
(For Full Load)
QUIET
CLEAN
1
2
1
2
(For Half Load)
(Auto OFF/ON Button)
POWER
TIMER
nanoe-G
PURIFIER
SLEEP /
POWERFUL
(Indication for Half load)
TWO LEDs FROM BOTTOM
STARTS BLINKING