SAvE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do
so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
This product meets the requirements of the PGMA (Portable Generator Manufacturers' Association) standard ANSI/PGMA G300-2015 (Safety and Performance of
Portable Generators).
Covered by one or more of the following U.S. Patent Numbers: 10,598,101, 10,221,780 and other U.S. and foreign patents pending.
REV 20201130
Champion Power Equipment, Inc., Santa Fe Springs, CA USA
Summary of Contents for Champion Global Power Equipment 201047
Page 1
OPERATOR'S MANUAL MODEL #201047 2400W DUAL FUEL INvERTER GENERATOR REGISTER YOUR PRODUCT ONLINE at championpowerequipment.com or visit championpowerequipment.com SAvE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do so could result in serious injury.
Page 2
CARBON MONOXIDE SAFETY: THE BIG PICTURE As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect your family from this colorless, oderless threat.
INTRODUCTION 201047 - 2400W DUAL FUEL INvERTER GENERATOR INTRODUCTION SAFETY DEFINITIONS Congratulations on your purchase of a Champion Power Equipment The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, (CPE) product. CPE designs, builds, and supports all of our products to strict specifications and guidelines.
IMPORTANT SAFETY INSTRUCTIONS 201047 - 2400W DUAL FUEL INvERTER GENERATOR IMPORTANT SAFETY INSTRUCTIONS DANGER Operate equipment with guards in place. WARNING Rotating parts can entangle hands, feet, hair, clothing and/or Cancer and Reproductive Harm – www.P65Warnings.ca.gov accessories. Traumatic amputation or severe laceration can result.
Page 6
IMPORTANT SAFETY INSTRUCTIONS 201047 - 2400W DUAL FUEL INvERTER GENERATOR WARNING CAUTION Spark from removed spark plug wire can result in fire or Start the generator and allow the engine to stabilize before electrical shock. connecting electrical loads.
IMPORTANT SAFETY INSTRUCTIONS 201047 - 2400W DUAL FUEL INvERTER GENERATOR Fuel Safety When adding or removing gasoline: DO NOT light or smoke cigarettes. DANGER Turn the generator off and let cool for at least two minutes before removing the gasoline cap. Always loosen the cap slowly to relieve GASOLINE, GASOLINE VAPORS AND PROPANE (LPG) ARE pressure in the tank.
IMPORTANT SAFETY INSTRUCTIONS 201047 - 2400W DUAL FUEL INvERTER GENERATOR Safety and Dataplate Labels These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement.
IMPORTANT SAFETY INSTRUCTIONS 201047 - 2400W DUAL FUEL INvERTER GENERATOR Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
IMPORTANT SAFETY INSTRUCTIONS 201047 - 2400W DUAL FUEL INvERTER GENERATOR Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
IMPORTANT SAFETY INSTRUCTIONS 201047 - 2400W DUAL FUEL INvERTER GENERATOR Quickstart Label Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
CONTROLS AND FEATURES 201047 - 2400W DUAL FUEL INvERTER GENERATOR CONTROLS AND FEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator 1.
CONTROLS AND FEATURES 201047 - 2400W DUAL FUEL INvERTER GENERATOR Control Panel 1. EZ Start Dial – Used to turn on gasoline or propane (LPG) RECEPTACLES fuel source, operate the choke, and stop the engine. 12V DC, 8A (Automotive) 2. Circuit Breakers (Push Reset) – Protects the generator May be used to supply electrical power for against electrical overloads.
CONTROLS AND FEATURES 201047 - 2400W DUAL FUEL INvERTER GENERATOR FCC Statement Parts Included 1. This device complies with Part 15 of the FCC Rules. Operation Accessories is subject to the following two conditions: 2.3 ft. (0.7 m) LPG Hose with Regulator ..
ASSEMbLY 201047 - 2400W DUAL FUEL INvERTER GENERATOR ASSEMbLY 1. Place the generator on a flat, level surface. 2. Turn the oil access cover fastener to the unlocked position Your generator requires some assembly. It must be properly and remove the cover.
ASSEMbLY 201047 - 2400W DUAL FUEL INvERTER GENERATOR 1. Remove the gasoline cap. NOTICE 2. Slowly add gasoline to the tank. DO NOT OVERFILL. Gasoline Check oil level often during the break-in period. Refer to the can expand after filling. A minimum of ¼ in. (6.4 mm) of Maintenance section for recommended service intervals.
ASSEMbLY 201047 - 2400W DUAL FUEL INvERTER GENERATOR WARNING Pouring gasoline too fast through the fuel screen may result in gasoline splashing over the generator and operator while filling. NOTICE The generator engine works well with 10% or less ethanol blended gasoline.
OPERATION 201047 - 2400W DUAL FUEL INvERTER GENERATOR Neutral Bonded to Frame* CAUTION – Neutral circuit IS electrically connected to the frame/ground of Use approved LPG cylinders equipped with an OPD (overfilling the generator. prevention device) valve. Always keep the cylinder in a vertical –...
OPERATION 201047 - 2400W DUAL FUEL INvERTER GENERATOR WARNING During operation the muffler and exhaust fumes will become hot. If adequate cooling and breathing space are not supplied, or if the generator is blocked or enclosed, temperatures can become extremely heated and may lead to fire.
OPERATION 201047 - 2400W DUAL FUEL INvERTER GENERATOR Cold Engine Start NOTICE 4. Move the EZ Start dial to the “CHOKE” position. Keep EZ Start dial in “CHOKE” position for only 1 pull of the recoil cord. If generator does not start after first pull, rotate the EZ Start dial to the “RUN”...
OPERATION 201047 - 2400W DUAL FUEL INvERTER GENERATOR Warm Engine Start NOTICE 4. Turn the EZ Start dial to the propane “RUN” position. Accumulation of frost on LPG cylinder and regulators is common during operation and normally is not an indication of a problem.
OPERATION 201047 - 2400W DUAL FUEL INvERTER GENERATOR WARNING Always remember to plug your appliances directly into the generator and do not plug the generator power cord into any electrical outlet or connect to the circuit breaker panel in your home.
“OFF” position when the generator is not in use. Parallel Operation Propane The Champion model 201047 is parallel ready and can be 1. Turn off and unplug all electrical loads. Never start or stop the operated in parallel with another Champion unit to increase the generator with electrical devices plugged in or turned on.
OPERATION 201047 - 2400W DUAL FUEL INvERTER GENERATOR Operation at High Altitude 4. Turn the EZ Start dial to the “STOP” position. The density of air at high altitudes is lower than at sea level. Engine power is reduced as the air mass and air-fuel ratio decrease.
MAINTENANCE 201047 - 2400W DUAL FUEL INvERTER GENERATOR MAINTENANCE 2. Turn the oil access cover fastener to the unlocked position and remove the cover. Make certain that the generator is kept clean and stored properly. 3. Remove oil fill cap/dipstick.
MAINTENANCE 201047 - 2400W DUAL FUEL INvERTER GENERATOR Cleaning and Adjusting the Spark Plug Cleaning the Air Filter 1. Remove the spark plug access cover. 1. Remove the non-recoil side cover. 2. Locate the air filter plastic cover. Loosen the retaining screw and pull the cover off.
STORAGE 201047 - 2400W DUAL FUEL INvERTER GENERATOR 6. Replace the spark arrestor if it is damaged. EVERY 50 HOURS OR ANNUALLY 7. Position the spark arrestor on the muffler and attach by Clean air filter reversing the steps from above.
STORAGE 201047 - 2400W DUAL FUEL INvERTER GENERATOR 3. Let the engine run on gasoline until fuel starvation has stopped the engine. Let the engine run on gasoline until fuel starvation has stopped the engine. 4. After the engine stops, turn the EZ Start dial to the “STOP”...
SPECIFICATIONS 201047 - 2400W DUAL FUEL INvERTER GENERATOR SPECIFICATIONS Oil Specifications DO NOT OVERFILL. Generator Specifications Type ..........*See following chart Generator Model ......... ..
TROUbLESHOOTING 201047 - 2400W DUAL FUEL INvERTER GENERATOR TROUbLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Low oil level. Place generator on a flat, level surface.
WARRANTY 201047 - 2400W DUAL FUEL INvERTER GENERATOR WARRANTY* Other Exclusions This warranty excludes: CHAMPION POWER EQUIPMENT – Cosmetic defects such as paint, decals, etc. 3 YEAR LIMITED WARRANTY – Wear items such as filter elements, o-rings, etc. Warranty Qualifications –...
Page 32
CHAMPION POWER EQUIPMENT, INC. (CPE), THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (U.S. EPA) AND THE CALIFORNIA AIR RESOURCES BOARD (CARB) EMISSION CONTROL SYSTEM WARRANTY Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board (CARB) emissions regulations.
Page 33
EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (SORE) (for other states, 1997 and later model year engines). The ECS Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
Page 34
EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the engine) Systems covered by this Parts Description warranty Fuel Metering System Fuel regulator, Carburetor and internal parts Air Induction System Air cleaner, Intake manifold Ignition System Spark plug and parts, Magneto ignition system Exhaust System Exhaust manifold, catalytic converter...