Champion Global Power Equipment 201230 Operator's Manual

Champion Global Power Equipment 201230 Operator's Manual

2000w dual fuel inverter generator

Advertisement

Quick Links

OPERATOR'S MANUAL
MODEL #201230
2000W DUAL FUEL INvERTER GENERATOR
REGISTER YOUR PRODUCT ONLINE
at championpowerequipment.com
o visite championpowerequipment.com
SAvE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do
so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
This product meets the requirements of the PGMA (Portable Generator Manufacturers' Association) standard ANSI/PGMA G300-2018 (Safety and Performance of
Portable Generators).
Covered by one or more of the following U.S. Patent Numbers: 10,641,187, 10,862,414 and other U.S. and foreign patents pending.
EN
4063-M-OP REV 20230302
Champion Power Equipment, Inc., Santa Fe Springs, CA USA

Advertisement

Table of Contents
loading

Summary of Contents for Champion Global Power Equipment 201230

  • Page 1 OPERATOR'S MANUAL MODEL #201230 2000W DUAL FUEL INvERTER GENERATOR REGISTER YOUR PRODUCT ONLINE at championpowerequipment.com o visite championpowerequipment.com SAvE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do so could result in serious injury.
  • Page 2 CARBON MONOXIDE SAFETY: THE BIG PICTURE As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect CARBON MONOXIDE K ILLS your family from this colorless, oderless threat.
  • Page 3: Table Of Contents

    TAbLE OF CONTENTS 201230 - 2000W DUAL FUEL INvERTER GENERATOR TAbLE OF CONTENTS Maintenance ..........Cleaning the Generator .......... Introduction ........... Changing the Engine Oil .........
  • Page 4: Introduction

    INTRODUCTION 201230 - 2000W DUAL FUEL INvERTER GENERATOR INTRODUCTION SAFETY DEFINITIONS Congratulations on your purchase of a Champion Power Equipment The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, (CPE) product. CPE designs, builds, and supports all of our products to strict specifications and guidelines.
  • Page 5: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS 201230 - 2000W DUAL FUEL INvERTER GENERATOR IMPORTANT SAFETY INSTRUCTIONS DANGER  Operate equipment with guards in place. DANGER  Rotating parts can entangle hands, feet, hair, clothing and/or Generator exhaust contains carbon monoxide, a colorless, accessories. Traumatic amputation or severe laceration can odorless, poisonous gas.
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS 201230 - 2000W DUAL FUEL INvERTER GENERATOR WARNING CAUTION   Spark from removed spark plug wire can result in fire or Start the generator and allow the engine to stabilize before electrical shock. connecting electrical loads.
  • Page 7: Fuel Safety

    IMPORTANT SAFETY INSTRUCTIONS 201230 - 2000W DUAL FUEL INvERTER GENERATOR Fuel Safety WARNING  DANGER Propane/LPG (liquified petroleum gas) and LPG Vapors:  – LPG is a hydrocarbon gas that exists in a liquified form and GASOLINE, GASOLINE VAPORS, AND PROPANE ARE HIGHLY it’s vapors are highly flammable and explosive.
  • Page 8 IMPORTANT SAFETY INSTRUCTIONS 201230 - 2000W DUAL FUEL INvERTER GENERATOR WARNING  When starting the generator: DO NOT attempt to start a damaged generator. Always check that the gasoline cap, air filter, spark plug, fuel lines and exhaust system are properly in place.
  • Page 9: Safety And Dataplate Labels

    IMPORTANT SAFETY INSTRUCTIONS 201230 - 2000W DUAL FUEL INvERTER GENERATOR Safety and Dataplate Labels These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement.
  • Page 10: Safety Symbols

    IMPORTANT SAFETY INSTRUCTIONS 201230 - 2000W DUAL FUEL INvERTER GENERATOR Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 11: Operation Symbols

    IMPORTANT SAFETY INSTRUCTIONS 201230 - 2000W DUAL FUEL INvERTER GENERATOR Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 12: Quickstart Label Symbols

    IMPORTANT SAFETY INSTRUCTIONS 201230 - 2000W DUAL FUEL INvERTER GENERATOR Quickstart Label Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 13: Controls And Features

    CONTROLS AND FEATURES 201230 - 2000W DUAL FUEL INvERTER GENERATOR CONTROLS AND FEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator 1.
  • Page 14: Control Panel

    CONTROLS AND FEATURES 201230 - 2000W DUAL FUEL INvERTER GENERATOR Control Panel 1. Circuit Breakers (Push Reset) – Protects the generator RECEPTACLES against electrical overloads. (2×) 120V AC, 20A (NEMA 5-20R) 2. Economy Mode Button – Enables/disables automatic idle May be used to supply electrical power for control.
  • Page 15: Industry Canada: Can Ices-002/Nmb-002

    CONTROLS AND FEATURES 201230 - 2000W DUAL FUEL INvERTER GENERATOR Industry Canada: CAN ICES-002/NMb-002 This device complies with Industry Canada license - exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2.
  • Page 16: Assembly

    ASSEMbLY 201230 - 2000W DUAL FUEL INvERTER GENERATOR ASSEMbLY 1. Place the generator on a flat, level surface. 2. Loosen the cover fasteners and remove the maintenance Your generator requires some assembly. This unit ships from our cover. factory without oil. It must be properly serviced with fuel and oil before operation.
  • Page 17: Add Fuel: Gasoline

    ASSEMbLY 201230 - 2000W DUAL FUEL INvERTER GENERATOR 1. Remove the gasoline cap. NOTICE  2. Slowly add gasoline to the tank. DO NOT OVERFILL. Gasoline Check oil level often during the break-in period. Refer to the can expand after filling. A minimum of ¼ in. (6.4 mm) of Maintenance section for recommended service intervals.
  • Page 18: Add Fuel: Propane (Lpg)

    ASSEMbLY 201230 - 2000W DUAL FUEL INvERTER GENERATOR NOTICE  The generator engine works well with 10% or less ethanol blended gasoline. When using ethanol-gasoline blends there are some issues worth noting: – Ethanol-gasoline blends can absorb more water than gasoline alone.
  • Page 19: Grounding

    OPERATION 201230 - 2000W DUAL FUEL INvERTER GENERATOR OPERATION WARNING  If there is a strong smell of LPG: Close valve on the cylinder. CO Shield - Carbon Monoxide (CO) Detection ® Check all connections for leaks by wetting the fittings with a and Auto-shutoff System solution of soap and water.
  • Page 20: Generator Location

    OPERATION 201230 - 2000W DUAL FUEL INvERTER GENERATOR Generator Location Move the generator far away to an open, outdoor area and point the exhaust away from people and buildings. Once relocated to a safe area, the generator can be restarted, and the proper WARNING ...
  • Page 21: Surge Protection

    OPERATION 201230 - 2000W DUAL FUEL INvERTER GENERATOR 4. Move the EZ Start dial to the “CHOKE” position. WARNING  Do not expose to rain or use in damp locations. Keep all objects a minimum of 5 feet (1.5m) away from the generator at all times.
  • Page 22: Starting The Engine: Propane (Lpg)

    OPERATION 201230 - 2000W DUAL FUEL INvERTER GENERATOR 5. Slowly pull the starter cord 3-5 times to prime the engine. NOTICE  For gasoline starting in standard ambient temperature >59°F (15°C): Keep EZ Start dial in “CHOKE” position for three pulls of the recoil cord.
  • Page 23: Connecting Electrical Loads

    OPERATION 201230 - 2000W DUAL FUEL INvERTER GENERATOR Connecting Electrical Loads NOTICE  Let the engine stabilize and warm up for a few minutes after Accumulation of frost on LPG cylinder and regulators is starting. common during operation and normally is not an indication Plug in and turn on the desired 120 or 240 (if applicable) Volt AC of a problem.
  • Page 24: Do Not Overload Generator

    Power Management Parallel Operation Use the following formula to convert voltage and amperage to The Champion model 201230 is parallel ready and can be watts: operated in parallel with another Champion unit to increase the total available electrical power. A Champion parallel kit (optional Volts ×...
  • Page 25: Stopping The Engine

    OPERATION 201230 - 2000W DUAL FUEL INvERTER GENERATOR Stopping the Engine 4. Turn the EZ Start dial counterclockwise to the “STOP” position. Gasoline 1. Turn off and unplug all electrical loads. Never start or stop the generator with electrical devices plugged in or turned on.
  • Page 26: Operation At High Altitude

    MAINTENANCE 201230 - 2000W DUAL FUEL INvERTER GENERATOR Operation at High Altitude NOTICE  The density of air at high altitudes is lower than at sea level. For Emission control devices and systems, read and Engine power is reduced as the air mass and air-fuel ratio understand your responsibilities for service as stated in the decrease.
  • Page 27: Cleaning And Adjusting The Spark Plug

    MAINTENANCE 201230 - 2000W DUAL FUEL INvERTER GENERATOR 4. Tilt the generator on its side and allow the oil to drain 4. Use a spark plug socket tool (not included), or a completely. 13/16 in. (21 mm) socket (not included) to remove the plug.
  • Page 28: Cleaning The Spark Arrestor

    MAINTENANCE 201230 - 2000W DUAL FUEL INvERTER GENERATOR Adjusting the Governor 3. Remove the foam element. 4. Wash in liquid detergent and water. Squeeze thoroughly dry in WARNING  a clean cloth. 5. Saturate in clean engine oil. Tampering with the factory set governor will void your warranty.
  • Page 29: Storage

    STORAGE 201230 - 2000W DUAL FUEL INvERTER GENERATOR Mid Term Storage (30 days – 1 year) EVERY 250 HOURS Ethanol blended gasoline in the tank has a maximum shelf life — Clean combustion chamber* of up to 1 year with the addition of a properly formulated fuel —...
  • Page 30: Lpg Storage

    STORAGE 201230 - 2000W DUAL FUEL INvERTER GENERATOR Removing from Storage: Propane (LPG) 6. When gasoline stops flowing from the clear tube, rotate drain screw clockwise until tight. Properly dispose of the drained Upon removal from storage, inspect LPG fittings and hose lines for gasoline according to local regulations or guidelines.
  • Page 31: Specifications

    SPECIFICATIONS 201230 - 2000W DUAL FUEL INvERTER GENERATOR SPECIFICATIONS Oil Specifications DO NOT OVERFILL. Generator Specifications Type ..........*See following chart Generator Model .......... .
  • Page 32: Troubleshooting

    TROUbLESHOOTING 201230 - 2000W DUAL FUEL INvERTER GENERATOR TROUbLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Low oil level. Place generator on a flat, level surface.
  • Page 33 TROUbLESHOOTING 201230 - 2000W DUAL FUEL INvERTER GENERATOR Problem Cause Solution Move generator to an open, outdoor area. Point exhaust away from people and buildings. Move to fresh air and get medical help if sick, dizzy, or weak. Make sure there are no objects creating obstructions within 5 feet of the generator.
  • Page 34 TROUbLESHOOTING 201230 - 2000W DUAL FUEL INvERTER GENERATOR Problem Cause Solution Engine governor defective. Contact the help line. Dirty fuel valve. Clean the fuel valve. Engine hunts or falters. Carburetor is dirty and running lean. Contact the help line. Choke in wrong position.
  • Page 35 WARRANTY* Other Exclusions This warranty excludes: CHAMPION POWER EQUIPMENT – Cosmetic defects such as paint, decals, etc. 3 YEAR LIMITED WARRANTY – Wear items such as filter elements, o-rings, etc. Warranty Qualifications – Accessory parts such as starting batteries, and storage To register your product for warranty and FREE lifetime call center covers.
  • Page 36 CHAMPION POWER EQUIPMENT, INC. (CPE) AND THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (U.S. EPA.) EMISSION CONTROL SYSTEM WARRANTY Your Champion Power Equipment (CPE) engine complies with U.S. EPA emissions regulations. YOUR WARRANTY RIGHTS AND OBLIGATIONS: The US EPA and CPE are pleased to explain the Federal Emission Control Systems Warranty on your 2023 small off-road engine and engine powered equipment.
  • Page 37 EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Exhaust and Evaporative Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1997 and later model year small off-road engines.The ECS Warranty Period shall begin on the date the new engine is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
  • Page 38 EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the engine) Systems covered by this Parts Description warranty Fuel Metering System Carburetor and internal parts (and/or pressure regulator or fuel injection system) Air/fuel ratio feedback and control system. Cold start enrichment system. Air Induction System Controlled hot air intake system.

Table of Contents