Dell PowerEdge 2200 Systems Service Manual
Table 3-2. System Error Messages (continued)
Message
Keyboard con-
troller error
Keyboard error
Memory size
limit exceeded
Operating sys-
tem not found
Processor bus
terminator
not installed
Processor X
temperature
sensor is not
installed
Real-time
clock error
Resource con-
flict
Stuck key
Definition
A cable may be loose,
the keyboard may be
faulty, or the keyboard
controller is defective.
A cable may be loose,
or the keyboard may be
faulty.
The size of installed
DIMM memory is
greater than
512 MB.
The system did not find
a bootable operating
system.
In a single micro-
processor system, a
terminator card is not
installed in the second-
ary microprocessor
connector.
The primary (X=1) or
secondary (X=2) micro-
processor's temperature
sensor is not connected
to the system board.
The real-time clock on
the system board mal-
functioned.
The BIOS detected a
resource conflict while
configuring a Plug and
Play ISA or PCI expan-
sion card.
A cable may be loose,
or the keyboard may be
faulty.
Probable Causes
Defective keyboard, key-
board cable, or system
board.
Defective keyboard, key-
board cable, or system
board.
Verify that the total
installed DIMM memory
does not exceed 512 MB.
Use a diskette with a
bootable operating sys-
tem on it in drive A, or
load a bootable operating
system from the hard-disk
drive.
Install a terminator card
in the secondary micro-
processor connector. See
"Microprocessor
Module" in Chapter 4.
Connect the micro-
processor's temperature
sensor to the appropriate
connector on the system
board. See "Micro-
processor Module" in
Chapter 4.
Defective micro-
processor or system
board.
See "Eliminating
Resource Conflicts" in
Chapter 2.
Defective keyboard or
keyboard cable.