Download Print this page

Larson Electronics EPLC2-LB-45LED-RT-WLM Instruction Manual

45w hazardous location low bay led fixture paint spray booth approved - 6,300 lms - wall mount - t5

Advertisement

Quick Links

45W Hazardous Location Low Bay LED Fixture
Paint Spray Booth Approved - 6,300 lms - Wall Mount - T5
The Larson Electronics EPLC2-LB-45LED-RT-WLM Hazardous Location Low Bay LED Light Fixture provides operators
with a powerful alternative to traditional hazardous location luminaries. Capable of replacing 250-watt metal halide lamps,
this 45-watt low bay LED unit emits 6,300 lumens, carries an IP67 waterproof rating and features an extended lifespan of
60,000+ hours. The factory sealed, hazardous location fixture is protected by a copper-free aluminum housing with an
epoxy powder coated finish.
WARNING
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE
REFERENCE. CRITICAL SAFETY INSTRUCTIONS:
INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY
RELEVANT LOCAL BUILDING CODES.
RISK OF FIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF LUMINAIRES ELECTRICAL
SYSTEMS. IF NOT QUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.
BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.
MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE RATED LUMINAIRE FIXTURES VOLTAGE.
TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP
OBJECTS. SUITABLE FOR DAMP LOCATIONS.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE. THE EPLC2-LB-45LED-RT-WLM MUST BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL
CODE AND ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.
WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS
PRODUCT. IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION SHEET,
CONSULT AN ELECTRICIAN. THERE ARE NO SERVICEABLE PARTS INSIDE.
WARNING: MAKE SURE POWER IS TURNED OFF BEFORE STARTING THE
INSTALLATION OR PERFORMING ANY MAINTENANCE.
RISK OF FIRE/ELECTRIC SHOCK –
RISK OF PERSONAL INJURY –
RISK OF BURN –
ALLOW FIXTURE TO COOL BEFORE SERVICING.
WIRING
Standard pigtail(flying leads) wiring
We strongly encourage a licensed electrician install this product
where weatherproofing may be required. Universal voltage driver permits operation at 100V - 277V AC, 50 or 60Hz
except those factory ordered with low voltage 11V to 25V AC/DC.
Warning: Check product label for correct input voltage!
Attach supply line wires to the appropriate light fixture wires as shown
in the diagram 
Secure each pair of wires according to the diagram. Utilize a junction box or
similar
device
and
take
connections if installed in a location where water may come in contact with the
unit. Ensure the unit is properly grounded and that wiring is done according to
all local and national electrical/building codes.
Larson Electronics, LLC
Instruction Manual
DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING.
FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROPERLY.
precautionary
steps
Phone: (800) 369-6671
, in all locations especially in outdoor areas
for
weatherproofing
all
Fax: (903) 498-3364
EPLC2-LB-45LED-RT-WLM
www.larsonelectronics.com
1 of 2

Advertisement

loading

Summary of Contents for Larson Electronics EPLC2-LB-45LED-RT-WLM

  • Page 1 Paint Spray Booth Approved - 6,300 lms - Wall Mount - T5 Instruction Manual The Larson Electronics EPLC2-LB-45LED-RT-WLM Hazardous Location Low Bay LED Light Fixture provides operators with a powerful alternative to traditional hazardous location luminaries. Capable of replacing 250-watt metal halide lamps, this 45-watt low bay LED unit emits 6,300 lumens, carries an IP67 waterproof rating and features an extended lifespan of 60,000+ hours.
  • Page 2 (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed. 4. Do not operate if the lens is cracked or damaged. All fasteners should be properly seated. 2 of 2 Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364...
  • Page 3 Larson Electronics. THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT SALES@LARSONELECTRONICS.COM OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE.