oap timer clock-sync

Use oap timer clock-sync to set the clock synchronization timer.
Use undo oap timer clock-sync to restore the default.
Syntax
oap timer clock-sync minutes
undo oap timer clock-sync
Default
The clock synchronization timer is set to 5 minutes.
Views
System view
Predefined user roles
network-admin
mdc-admin
Parameters
minutes: Specifies the clock synchronization timer value in minutes, in the range of 0 to 1440.
Setting this argument to 0 disables clock synchronization.
Usage guidelines
The clock synchronization timer regularly triggers the OAP manager to send clock and time zone
synchronization notifications to OAP clients. These notifications keep the clients' clocks
synchronized to the manager's clock.
Examples
# Set the clock synchronization timer to 20 minutes.
<Sysname> system-view
[Sysname] oap timer clock-sync 20

oap timer monitor

Use oap timer monitor to set the client monitoring timer.
Use undo oap timer monitor to restore the default.
Syntax
oap timer monitor seconds
undo oap timer monitor
Default
The client monitoring timer is set to 5 seconds.