It is designed to be used both in gas and dust environments, zones 1, 2, 21 and 22. Read this user guide to get the most out of your RLX DxZ1.21 LED floodlight and help it to maximize its potential for your application.
For EMC compliance to MIL-STD461F Navy Mobil & Army, overall screening must be terminated 360° in the cable gland. Page 3 of 9 Luminell Norway AS Doc. Nr.: L0482 – RLX DxZ1.21 User Manual v.1.7...
– this for the highest possible cooling performance. For detailed mechanical drawings see appendix. The RLX DxZ1.21 may be mounted in any direction, however it is recommended to point the cable glands downwards.
A startup current is needed to energize the electronics inside the RLX DxZ1.21 LED floodlight. When using a MCB16 Type C fuse, approx. 11 RLX DxZ1.21 floodlights can be started at once. The inrush current is the equal for all power alternatives.
10 T EMPERATURE PROTECTIVE DEVICES For hazardous safety and lifetime optimization the RLX DxZ1.21 LED floodlight is equipped with several temperature protective devices. Two individual temperature controls may have influence on the use of the floodlight. Automated Temperature Control RLX DxZ1.21...
1002600 Connection box gel kit 1002322 Pole Mount bracket Ø30-Ø100 Protection Guard Set 1002629 Retrofit bracket 130, 160 to 225-260, 350-380, 435 L0433 Oil Damper Single Bracket Assembly Page 8 of 9 Luminell Norway AS Doc. Nr.: L0482 – RLX DxZ1.21 User Manual v.1.7...
Page 9
13.4 L IGHT LLUSTRATIONS Structured glass Clear glass Types: Types: Oval 45x15 Spot 15 Medium 60x40 Medium 40 Wide 80x60 Medium 60 Page 9 of 9 Luminell Norway AS Doc. Nr.: L0482 – RLX DxZ1.21 User Manual v.1.7...