Daikin RXR28EV1B9 Service Manual Removal Procedure page 33

2.8/4.2/5.0 kw class
Hide thumbs Also See for RXR28EV1B9:
Table of Contents

Advertisement

Si00-777
Step
Before working, make sure
that the refrigerant gas is
empty in the circuit.
Be sure to apply nitrogen
replacement when heating
up the brazed part.
Heat up the 4 brazed
4
parts of the four way
valve. Disconnect them
in the order of (a) (b)
(c) (d).
Note:
Do not use a metal saw for
cutting pipes by all means
because the sawdust
comes into the circuit.
When withdrawing the
pipes, be careful not to
pinch them firmly with
pliers. The pipes may get
deformed.
Provide a protective sheet
or a steel plate so that the
brazing flame cannot
influence peripheries.
Removal Procedure
Procedure
(a)
(b)
(c)
Removal of Four Way Valve
Warning
Be careful not to get yourself
burnt with the pipes and
other parts that are heated by
the gas brazing machine.
Warning
If the refrigerant gas leaks
during work, ventilate the
room. (If the refrigerant gas
is exposed to flames, toxic
gas may be generated.)
(R14027)
Caution
From the viewpoint of global
environment protection, do
not discharge the refrigerant
gas in the atmosphere. Make
sure to collect all the
refrigerant gas.
Cautions for restoration
1. Restore the piping by non-
oxidation brazing.
2. It is required to prevent the
carbonization of the oil
(R14028)
inside the four way valve
and the deterioration of the
gaskets affected by heat.
(Keep below 120°C.) For
the sake of this, wrap the
four way valve with wet
(d)
cloth and provide water so
that the cloth does not dry.
In case of difficulty with gas
brazing machine
1. Disconnect the brazed part
where is easy to disconnect
and restore.
2. Cut pipes on the main unit
with a tube cutter in order to
(R14029)
make it easy to disconnect.
Points
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rxr42ev1b9Rxr50ev1b9Rxr28fvltRxr50fvlt