), and the status indicators on the module. FEATURES AND BENEFITS • LEDs for easy annunciation of power, faults and • Expands the capabilities of Det-Tronics’ Eagle active devices on the loop Quantum Premier system • Monitors single addressable devices •...
See Figure 3 NODE 3 NODE 6 for Class B pathway. NODE 4 NODE 2 NODE 7 CONTROLLER SINGLE ASH MODULE DET-TRONICS ® ZONE EAGLE QUANTUM PREMIER Safety System Controller NODE 8 NODE 1 Eagle Quantum Premier Fire Alarm Trouble...
Class X is intended for use in a multi-zone system and requires that the first isolator on each leg be installed next to the ASH Module, within the same enclosure. In addition, an isolator is needed between each zone as illustrated in Figure 4.
Page 5
Table 3—List of Supported Devices DET-TRONICS APOLLO DEVICE NAME PART NUMBER PART NUMBER 000515-501 58000-500 Apollo Ionization Smoke, EU 000515-502 58000-600 Apollo Optical Smoke Detector, EU 000515-503 58000-400 Apollo Heat Detector, EU 000515-504 58000-700 Apollo Multisensor, EU 000515-505 58000-300 Apollo Carbon Monoxide Detector, EU...
CONTROL MESSAGE NOTE If there is an active alarm, any new integrity The control message manages loop device specific check request is ignored. If an integrity check is commands, such as integrity check, LED, relay and sound in progress and an alarm condition occurs, the control.
HUMIDITY RANGE— EQ3750ASH 5 to 95% RH, non-condensing SHLD SHLD 24 VDC – – DIMENSIONS— INPUT VOLTAGE See Figure 6 SHLD SHLD 24 VDC – – SHIPPING WEIGHT— INPUT VOLTAGE 2.7 pounds (1.22 kilograms) POWER COM 1 SHLD SHLD CERTIFICATION — LON FROM COM 1 B PREVIOUS DEVICE...
Page 8
All Discovery detectors have a sensitivity parameter that may be set to 1 of 5 different levels. The most sensitive Det-Tronics’ S Safety System Software is used for device level is 1, and the least sensitive level is 5. The default configuration.
Where applicable, use an antistatic bag as protection from electrostatic discharge. NOTE Det-Tronics reserves the right to apply a service charge for repairing returned product damaged as a result of improper packaging. Return all equipment transportation prepaid to the factory...
Page 10
EQUIPMENT SAFETY SYMBOLS Symbol Description Direct current Alternating current Both direct and alternating current Three-phase alternating current Earth (ground) current Protective conductor terminal Frame or chassis terminal On (power) O (power) Equipment protected throughout by double insulation or reinforced insulation Caution, possibility of electric shock Caution, hot surface Caution*...
Need help?
Do you have a question about the Eagle Quantum Premier EQ3750ASH and is the answer not in the manual?
Questions and answers