Sign In
Upload
Manuals
Brands
Det-Tronics Manuals
Control Unit
Eagle Quantum Premier EQ3750ASH
Det-Tronics Eagle Quantum Premier EQ3750ASH Manuals
Manuals and User Guides for Det-Tronics Eagle Quantum Premier EQ3750ASH. We have
2
Det-Tronics Eagle Quantum Premier EQ3750ASH manuals available for free PDF download: Instructions Manual
Det-Tronics Eagle Quantum Premier EQ3750ASH Instructions Manual (145 pages)
Fire and Gas Alarm Control System and Automatic Releasing for Pre-Action and Deluge Systems
Brand:
Det-Tronics
| Category:
Control Systems
| Size: 8 MB
Table of Contents
Table of Contents
2
Section 1 Safety
6
Alert Messages
6
Section 2 Introduction
7
System Description
7
Communications Loop
7
LON Communication Heartbeat
8
Theory of Operation
9
Controller Logs
10
Controller User Logic
10
Communication Network Fault Operation
11
Multiple Wiring Faults
11
SIL2 Capable System
11
Major Component Descriptions
12
System Controller
12
Controller Redundancy
12
Ethernet Interface Board
13
Serial Interface Board
13
Controlnet Board or Ethernet DLR Board
13
Controller-To-Controller Communication
14
EQP Marine Application System
14
Local Operating Network (LON)
14
Network Extender (NE)
14
Physical Layer Repeater (PLR)
14
Eq21Xxps Series Power Supplies and EQ2100PSM Power Supply Monitor
15
Eqp21Xxps(-X) Power Supplies and EQP2410PS(-P) Converter
15
EQ2220GFM Ground Fault Monitor
15
Field Devices
15
Flame Detectors
15
EQ2200UVHT + C7050 Detector
15
Model HD Heat Detector
16
U5015 Explosion-Proof Smoke Detector
16
X7050 Xwatch Explosion-Proof Camera
16
EQ3700 8 Channel DCIO Module
16
EQ3720 8 Channel Relay Module
17
EQ3710AIM Analog Input Module
18
EQ3770 Explosion-Proof I/O (EIO) Module
18
EQ3760ASM Addressable Smoke and Heat Module
19
EQ3750ASH Addressable Smoke and Heat Module
19
Eq22Xxarm Agent Release Module
20
Eq22Xxsam Signal Audible Module
21
Eq22Xxidc Series Initiating Device Circuit
21
UD10 DCU Emulator
22
Eq22Xxdcu and Eq22Xxdcuex
22
Digital Communication Units
22
PIRECL Pointwatch Eclipse
23
LS2000 Line-Of-Sight
23
EQ3900 Series Fire and Gas Alarm Control Panel and
23
Pre-Action System Solutions
23
EQ3900RPS Explosion-Proof Power Supply
23
EQ3780HSDM High Speed Deluge Module
23
Section 3 Installation
24
Safety System Design Requirements
24
Identifying the Area of Protection
24
Identifying Wiring, Network (LON)
24
And System Power Requirements
24
General Wiring Requirements
24
Power Wiring
24
System Wiring (ATEX and Iecex)
24
Determining Power Requirements
26
Eq211Xps, Eq213Xps and Eq217Xps
28
Power Supplies
28
Backup Battery
28
Battery Charger
28
Eqp21X0Ps(-X) Power Supplies
28
EQP2410PS(-P) Converter
29
Determining Power Requirements
29
Shield Grounding
30
Junction Box Grounding
30
Response Time Vs. System Size
30
Moisture Damage Protection
30
Electrostatic Discharge
30
Ground Fault Monitor (Gfm) Installation
31
Mounting
31
Wiring
31
Network & Network Extender Installation
31
Mounting
34
Serial Interface Board
34
Ethernet Interface Board
34
Wiring
34
Power Wiring
34
Electrical Connections
34
Controller to Controller Communication
39
Configuration
43
Software Defined Addresses
43
Eq3Xxx Redundant Controller Installation
45
Enclosure Requirements
45
Mounting
45
Wiring
45
LON Wiring
45
High Speed Serial Link (HSSL)
46
Configuration
46
Controller Addresses
46
Controlnet
46
Ethernet DLR
46
Ethernet
46
Eq21Xxps Series Power Supply and Power Supply Monitor Installation
46
Mounting
47
Wiring
47
Startup
47
Measuring Battery Voltage and Charging Current
48
Eqp2Xx0Ps(-X) Power Supplies and Redundancy Module Installation
49
Mounting
49
Wiring
49
Startup
52
Configuration
56
Mounting
56
Wiring
57
Configuration
61
Channel Relay Module Installation
61
Mounting
61
Wiring
61
Configuration
62
Mounting
62
Wiring
63
Configuration
64
Gas Detector Location and Installation
65
Environments and Substances that Affect Gas Detector Performance
65
Eq22Xxdcu Digital Communication Unit Used with Det-Tronics H2S/O2 Sensors or Other Two-Wire 4-20 Ma Devices
66
Assembly and Wiring Procedure
66
Sensor Separation for DCU with H2S and O2 Sensors
68
Eq22Xxdcu Digital Communication Unit Used with Pointwatch/Ductwatch
68
Assembly and Wiring Procedure
68
Eq22Xxdcuex Digital Communication Unit (Used with Det-Tronics Combustible Gas Sensors)
69
Mounting
69
Wiring
69
Sensor Separation with DCUEX
70
Preferred Method
70
Alternate Method
71
Typical Applications
71
System Configuration
73
Setting Device Network Addresses
73
Overview of Network Addresses
73
Setting Field Device Addresses
73
Rocker Switch Table
74
Section 4 Operation
76
System Controller
76
Pushbuttons
76
Controller Status Indicators
77
Text Display
77
Controller Menu Options
77
Alarm Type
79
Display Devices
79
Controller Audible Alarm
81
Controlnet Status Indicators (Optional)
82
Ethernet DLR Status Indicators
82
Sequence of Events During a Configuration Data Download
83
Controller Redundancy
84
Enhanced Discrete I/O Module
86
Power-Up Sequence
86
Channel Dcio Module
87
Power-Up Sequence
87
Channel Relay Module
88
Power-Up Sequence
88
Analog Input Module
89
Power-Up Sequence
89
Eq21Xxpsm Power Supply Monitor
90
Eq2220Gfm Ground Fault Monitor
90
Eq22Xxdcu and Eq22Xxdcuex Digital Communication Units
91
Eq24Xxne Network Extender/Eq24Xxplr Physical Layer Repeater
91
System Startup
92
Pre-Operation Checks
92
General Start-Up Procedures
93
Startup Procedure for Controller
94
Startup Procedure for EDIO Module
94
Startup Procedure for DCIO Module
95
Relay Module Startup
96
Analog Input Module Startup
96
Section 5 Maintenance
97
Routine Maintenance
97
Batteries
97
Manual Check of Output Devices
97
O-Ring Maintenance
97
Gas Sensor Maintenance
97
Calibration and Adjustments
98
Calibration Algorithm Afor Manual Calibration of Universal Dcu
98
Normal Calibration
98
Sensor Replacement
99
CALIBRATION ALGORITHM CFOR COMBUSTIBLE GAS DCUS and AUTOMATIC CALIBRATION of UNIVERSAL Dcus
99
Routine Calibration
99
Initial Installation and Sensor Replacement - Combustible Gas
100
Sensor Replacement - Toxic Gas
101
Calibration Algorithm D for Universal Dcus
101
With O2 Sensor
101
Normal Calibration
101
Sensor Replacement
101
CALIBRATION ALGORITHM GFOR Dcus with POINTWATCH or DUCTWATCH
102
Routine Calibration
102
Sensor Replacement
102
Device Calibration Logs and Records
103
Troubleshooting
103
Replacement Parts
103
Device Repair and Return
103
Ordering Information
105
Power Supplies
105
LON Devices
105
Redundancy
105
Controller Communication Cables
105
Section 6 Specifications
106
EQ3XXX Controller
106
EQ3LTM LON Termination Module
108
Input, Types
109
Output Style
109
Response Time
109
EQ3720 Relay Module
112
EQ3710AIM Analog Input Module
112
HART Interface Module
113
Eq21Xxps Power Supplies
113
Eqp2Xx0Ps(-X) Power Supplies
114
Redundancy Module Quint-Diode/40
114
Eq2230Rsp Module
114
Eq21Xxpsm Power Supply Monitor
115
EQ2220GFM Ground Fault Monitor
115
Eq24Xxne Network Extender/Eq24Xxplr Physical Layer Repeater
117
EQ3780HSDM High Speed Deluge Module
118
Combustible Gas Sensor
118
Electrochemical Sensors
118
UD10-DCU Universal Display
118
Eq21Xxps Power Supply
118
Section 7 Ordering Information
119
Type Approvals
119
Model Description
120
Gas Detection
122
Hazardous Locations
127
Special Conditions for Safe Use
131
System Specification
136
Power Requirement
137
Appendix Ece Mark
144
Advertisement
Det-Tronics Eagle Quantum Premier EQ3750ASH Instructions Manual (12 pages)
Addressable Smoke & Heat (ASH) Module
Brand:
Det-Tronics
| Category:
Control Unit
| Size: 1 MB
Table of Contents
Features and Benefits
2
Theory of Operation
3
Led Indicators
4
Specifications
6
Input Voltage
6
Temperature Range
6
Humidity Range
7
Shipping Weight
7
Installation
7
Maintenance
9
Ordering Information
9
Replacement Parts
9
Device Repair and Return
9
Advertisement
Related Products
Det-Tronics Eagle Quantum Premier EQ3760ASM
Det-Tronics Eagle Quantum Premier EQ3780HSDM
Det-Tronics Eagle Quantum Premier EQ3900K Series
Det-Tronics Eagle Quantum Premier
Det-Tronics Eagle Quantum Premier Safety System Controller
Det-Tronics EQ3LTM
Det-Tronics Eagle 2000
Det-Tronics Categories
Security Sensors
Gas Detectors
Measuring Instruments
Control Unit
Controller
More Det-Tronics Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL