  • Page 1 User Manual X2 dp Version 4.1 07.04.2020...
  • Page 2: Table Of Contents

    X2 dp 1 Contents Contents Contents .......................... 2 Foreword .......................... 3 Safety instructions ......................4 Connectors/Indicators ....................6 Connection panel ........................6 Connectors ..........................7 Controls ........................... 8 Status indication ........................8 Operation ......................... 9 Starting up..........................9 Selecting a bank ........................9 Setting level ..........................
  • Page 3: Foreword

    DSP configuration of your controller, you can obtain a fresh default file from SEEBURG acoustic line and re-install the original factory pre- sets yourself. Efficient and intelligent limiter functions provide optimal protection without sacrificing any of the potential of the system.
  • Page 4: Safety Instructions

    X2 dp 3 Safety instructions Safety instructions Acoustic Even a low input level can result in a sound pressure level at the loudspeaker which can be damaging to your hearing. Do not remain in close proximity to the loudspeaker when it is being operated. Use hearing protection.
  • Page 5 X2 dp 3 Safety instructions If the loudspeaker is connected to a power source in which the volt- age is too high, a protective mechanism is triggered which reliably safeguards the amplifier module and DSP. Once triggered, the pro- tection must be renewed by a qualified service technician.
  • Page 6: Connectors/Indicators

    X2 dp 4 Connectors/Indicators Connectors/Indicators 4.1 Connection panel Status indication and control panel PowerCon blue (3) RJ45 socket (2) XLR socket (1)
  • Page 7: Connectors

    6 dBu distortion free output voltage. RJ45 socket (2) This socket is used to integrate the X2 dp into an existing digital audio and control network. Digital audio signals (AES67 standard) can optionally be processed by the X2 dp.
  • Page 8: Controls

    X2 dp 4 Connectors/Indicators 4.3 Controls Mode button: Switch between the modes Status / Level and Presets. Set button: Set various values and Mute on/off. 4.4 Status indication Mute LED: Lights red when the system is muted (press the Set button in Status Mode), or in technically critical conditions.
  • Page 9: Operation

    X2 dp 5 Operation Operation 5.1 Starting up When the system is switched on, it retains the settings from the previous usage. This also applies to the Bank selection. The system is then in the Status Mode. If the red Mute LED is lit as a result of the previous setting, no signal will be passed.
  • Page 10: Setting Level

    5 Operation 5.3 Setting level After switching on and starting up, the X2 dp is in Status Mode. Press- ing the Mode button once selects the Level Mode, in which you can adjust the output volume in 3 dB steps. Seven different values between +6 dB and -12 dB are available, with 0 dB being the standard setting.
  • Page 11: Recalling Presets

    5 Operation 5.4 Recalling presets After switching on and starting up, the X2 dp is in Status Mode. Pressing the Mode button twice to selects the Preset Mode. Three different presets can be called up using the set button. The green LED above on the right indicates that you are in Preset Mode.
  • Page 12: Reprogramming Of Dp-Speakers With Preset Audio Files

    3. Make sure your computer's volume is set to 100%. 4. Load the ".wav" file received from SEEBURG acoustic line into a music player. 5. Press the play button. 6. After a successful programming operation, the Mute LED turns off.
  • Page 13: Technical Specifications

    X2 dp 6 Technical specifications Technical specifications 8“ Nd (2,5“ VC) / 1“ Nd (1,7“ VC) Speaker Components Description Multifunctional Coaxial Sound System Amp Power LF: 500 W AES / 110-230 V HF: 220 W AES / 110-230 V Rated Current...
  • Page 14: Declaration Of Conformity

     DIN EN 60065  DIN EN 55103-1:1996, classes E1 to E4  DIN EN 55103-2:1996, classes E1 to E4 Declared by: Winfried Seeburg, SEEBURG acoustic line GmbH Place and date: Senden, 01.10.2019 Legally binding sign: ____________________________________________ The attachments constitute part of this declaration. This declaration certifies conformity with the listed guidelines, but does not guarantee any product characteristics.