Installation of Indoor, Outdoor Unit

Selection of the best location
1) Indoor unit
• There should not be any heat source or steam
near the unit.
• There should not be any obstacles to prevent
the air circulation.
• A place where air circulation in the room will
be good.
• A place where drainage can be easily
obtained.
• A place where noise prevention is taken into
consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from
the wall, ceiling, or other obstacles.
• The indoor unit must keep the maintenance
space.
2) Outdoor unit
• If an awning is built over the unit to prevent
direct sunlight or rain exposure, be careful that
heat radiation from the condenser is not
restricted.
• There should not be any animals or plants
which could be affected by hot air discharged.
• Ensure the spaces indicated by arrows from
the wall, ceiling, fence or other obstacles.
h Please use an annexed sheet or the
corrugated cardboard on the bottom of
packing as installation sheet.
Annexed sheet
8 Ceiling Cassette Air Conditioner
Or
Packing corrugated
cardboard on the
bottom
Ceiling
Ceiling Board
500 or
more
More than
300mm
F e
n c
o b
e o
s t a
r
c l e
s
h When using the bottom sheet, please use it
after separating the installation sheet from
packing of the product floor by using a knife
etc as a picture below.
Ceiling Board
500 or
more
Unit:mm
Floor
More than
More than
More than
300mm
300mmm
300mmm
More than 600mm
More than 700mm

Advertisement