Replacing The Fuse; Dmx Linking; Master/Slave Connection - Chauvet Ovation P-56FC Quick Reference Manual

Hide thumbs Also See for Ovation P-56FC:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
Power Linking
It is possible to link up to 9 Ovation P-56FC products at 120 VAC, 16 products at 208 V, or 17 products at 230 VAC. Never
exceed this number. Power-linking cords can be purchased separately.
AC Plug
Connection
AC Live
AC Neutral
AC Ground
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
disconnect the product from power via breaker or by unplugging it.

Replacing the Fuse

1.
Disconnect this product from power.
2.
Using a flathead screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove blown fuse and replace with a good fuse of the same type and rating.
4.
Screw the fuse holder cap back in place and reconnect power.

DMX Linking

The Ovation P-56FC will work with a DMX controller using a 3- and 5-pin DMX serial connection. A DMX Primer is
available from www.chauvetprofessional.com.
DMX Connection
The Ovation P-56FC uses a 3- and 5-pin DMX data connection for its DMX personalities: 2Ch, 4Ch, 5Ch, 8Ch, 11Ch,
13Ch, 14Ch, 16Ch, and HSV. See the User Manual for information about connecting and configuring the product for
DMX operation.

Master/Slave Connection

The Ovation P-56FC uses the DMX data connection for its master/slave mode. See the User Manual for information
about how to connect and configure the product for master/slave operation.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. Check with the manufacturer or the DMX controller's User Manual, as not all DMX controllers
have this capability. The Ovation P-56FC supports RDM protocol that allows feedback to make changes to menu map
options. Download the User Manual from
Ovation P-56FC QRG Rev. 7
QUICK REFERENCE GUIDE
Wire (U.S.)
Black
White
Green/Yellow
www.chauvetprofessional.com
Wire (Europe)
Brown
Blue
Green/Yellow
for more details.
EN
Screw Color
Yellow/Brass
Silver
Green
2

Advertisement

Table of Contents
loading