Graco Eagle C Series Instructions-Parts List Manual page 22

50:1 ratio double acting grease pump
Table of Contents

Advertisement

Disassembly
1. Remove the actuator valve plug (11) from the top
cap (3). Inspect the sealing gasket (15*) and
spring (16*) in place on the plug. If the gasket
needs replacement, thread it off the plug (11). See
Fig. 11.
2. Pull the pin (12*) out of the top cap (3). Remove
the two o-rings (23*) from the pin.
3. If it is necessary to remove the o-ring (24*) from
the actuator valve cavity, you must first remove the
top cap. See Cylinder and Piston Service.
4. Repeat for the bottom cylinder cap (4).
Air Motor Service
Actuator Valve Service
Reassembly
1. If the o-ring (24*) was removed, it must be
installed from the inside of the top cap (3). Lubri-
cate the o-ring. See Fig. 11. Reinstall the top cap.
See Cylinder and Piston Service.
2. Install the two o-rings (23*) on the pin (12*).
Grease the pin and insert it in the top cap (3). The
long end must point toward the inside of the motor.
3. Thread the gasket (15*) onto the plug (11). Grease
the spring (16*) and install it in the plug. Screw the
plug into the top cap (3) and torque to 60 to 80
in-lb (6.8 to 9.0 N-m).
4. Repeat for the bottom cylinder cap (4).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eagle 235-888Eagle 235-889Eagle 235-890

Table of Contents