Battery Connection - Tripp Lite PINV2000 Owner's Manual

Dc-to-ac inverters
Hide thumbs Also See for PINV2000:
Table of Contents

Advertisement

Available languages

Available languages

Battery Connection

WARNING!
Make sure the inverter power switch is in the OFF position,
connect with included DC Wiring to the positive and negative
terminals. Though your Inverter is a high-efficiency converter
of electricity, its rated output capacity is limited by the length
and gauge of the cabling running from the battery to the unit.
Use the included cabling or the shortest length and largest
diameter cabling (see the Recommended Cabling and Fusing
Chart below) with ring terminals to fit your Inverter's DC Input
terminals. Shorter and heavier gauge cabling reduces DC voltage
drop and allows for maximum transfer of current. Your Inverter
is capable of delivering peak wattage at up to 200% of its rated
continuous wattage output for brief periods of time. Heavier
gauge cabling should be used when continuously operating heavy
draw equipment under these conditions. To protect the battery
system, it is also recommended to install a user-supplied UL-
rated ANL fuse and fuse block 7 inches from the battery bank's
positive terminal connection. The inverter has its own internal DC
fusing to protect against short circuits at the inverter's output.
Recommended Cabling and Fusing
Model
PINV2000
PINV2000HS
PINV3000
19-04-283-9338A1.indb 14
Included Wire
Gauge and Quantity
(2x Red / 2x Black)
4x 6 AWG
4x 5 AWG
4x 5 AWG
Included
Recommended
Cabling
DC Fuse Size
Length
(User-Supplied)
3 ft.
300A ANL Fuse
(1m)
3 ft.
440A ANL Fuse
(1m)
3 ft.
440A ANL Fuse
(1m)
14
Ground
Wire Size
and Length
(Included)
16 AWG
(3 ft.)
16 AWG
(3 ft.)
16 AWG
(3 ft.)