PELLET STOVES, bearing the EDILKAMIN brand, called VYDA AIR TIGHT SERIAL NO.: Rating plate reference VYDA AIR TIGHT : Performance declaration: (DoP - EK no. 161) Moreover, the company hereby declares that: the VYDA AIR TIGHT wood pellet stoves satisfy the...
Page 3
First ignition is required for activation of the Edilkamin manual, observe local regulations. manufacturer warranty. The warranty is only valid in the The diagrams provided in this manual are for illustration country where the product was bought.
• Blocking the aeration vents and air refer to the warranty certificate inside the intakes in the room. DO NOT BLOCK product: specifically, neither Edilkamin nor THE AERATION VENTS OR FLUE. Risk the retailer are liable for damage resulting of smoke returning into the room with from incorrect installation or maintenance.
DIMENSIONS VYDA AIR TIGHT- DIMENSIONS (cm) Ø 6 cm combustion air Ø 8 cm standard smoke discharge Ø 8 /13 cm smoke discharge with optional USER/INSTALLER...
Fuse 4 AT 250 V AC 5x20 The above data is for guidance only and was measured during certification by a notified body. EDILKAMIN s.p.a. reserves the right to modify the product without notification in the interests of improvement. USER/INSTALLER...
UNPACKING PREPARATION AND UNPACKING The packaging materials are neither toxic nor noxious and do not require special disposal. The end user is responsible for storing, disposing of and recycling them in a regulatory fashion. Always move the stove in an upright position with suitable equipment and in observance of safety regulations.
Page 8
UNPACKING DO NOT TRY TO REMOVE THE PRODUCT FROM THE PALLET WITHOUT HAVING REMOVED THE SIDE PANELS AND REMOVED THE SCREWS WHICH SECURE IT TO THE PALLET TO REMOVE THE STOVE FROM THE PALLET To remove the stove from the pallet 1.
Contact the retailer for this type of optional. Remember that Vyda Air Tight is sealed, in other words, if it is installed correctly with the air inlet pipe Positioning the product...
Page 10
INSTALLATION INSTRUCTIONS FOR THE SMOKE DISCHARGE THE FUMES DUCT WITH OR WITHOUT CONCENTRIC PIPE Further to the general prescriptions for the fumes duct and flue, the fumes duct: FLUE SYSTEM • may not be made of flexible metal material (Fumes duct, flue and chimney pot) •...
Page 11
INSTALLATION INTUBATED SYSTEM: Further to the general prescriptions for the fumes duct and flue, the intubated system: • must operate in negative pressure; • must be open to inspection; • must observe local regulations. THE CHIMNEY POT (In every country and specially in France, check on the specific waiver conditions) •...
Page 12
INSTALLATION COMBUSTION AIR INTAKE USE OF CONCENTRIC PIPES The inflow of necessary air for combustion, of air for Without prejudice to the general instructions, you can glass cleaning and heating air renewal must come use concentric pipes (which provide for the passage of from the outside smoke inside and the passage of the combustion air into the external circular ring).
Page 13
INSTALLATION Examples of possible installations. For the smoke discharge conditions (on roof, etc.) check local regulations for sealed pellet stoves. stufa stufa rear smoke discharge pipe scarico fumi dietro scarico fumi sopra presa aria dietro (diretta o indiretta) presa aria dietro (diretta rear air intake (direct or indirect) senza uso coassiale senza uso coassiale...
Page 14
The electrical system must be compliant; check the operation of the earth in particular. Edilkamin is not responsible for malfunctions resulting from an improperly earthed system. The power line must be of adequate section for the power of the appliance.
Page 15
VYDA - CLADDING Description Reference in the Quantity Figure below Front panel above the door (ceramic or stone) Top front panel (ceramic or stone) with metal bracket fitted Left or right interchangeable side panels (ceramic or stone) with metal bracket fitted Top (ceramic or stone) * Small parts: •...
Page 16
VYDA - CLADDING Fitting of the stone or ceramic front panel above THE DRAWINGS ARE FOR GUIDANCE ONLY, the door (1) USEFUL FOR THE INSTALLATION, BUT THEY MAY NOT REFER TO THE SPECIFIC MODEL. 1. Open the combustion chamber door with the protective lever (removable handle P) and undo two screws to remove “aesthetic cover”.
Page 17
VYDA - CLADDING 3. Refit the “aesthetic cover” aesthetic cover 4. Screw it back with the two screws removed in point 1 INSTALLER...
Page 18
VYDA - CLADDING Fitting of the stone or ceramic top front panel (2) 1. Slide the top metal plate towards the front(*) 2. Undo the two front screws which will be used to view from below secure the front panel 3.
Page 19
VYDA - CLADDING Fitting of the stone or ceramic sides (3) The sides (4) are only hooked on. 1. Place the rubber buffers and hook the sides to the structure rubber elements To make alignment adjustments between ceramic/ stone and the door, you can move the top or bottom screws of the bracket fixed to the structure.
Page 20
VYDA - CLADDING Fitting of the stone or ceramic top (4) 1. While keeping the top metal plate in a forward position, place the top and fit it with the screws underneath. For ceramic top For stone For stone ceramic For ceramic top INSTALLER...
Page 21
USER INSTRUCTIONS FIRST IGNITION (COMMISSIONING) PHAS- LOADING THE PELLETS INTO THE TANK. Slide the top * to load the pellets • Make sure you have read and understood this manual • Remove all flammable materials from the appliance (manuals, labels, etc.). In particular remove any labels from the glass •...
Page 22
USER INSTRUCTIONS OPERATION PHASES Further to the above operational procedures, the stove has the following phases Description. The access to and adjustment of these functions is described below: - Ignition (display reads ON ) Flame ignites and grows stable Mode Size settings This is the result of: MANUAL...
Page 23
• Open the bottom of the remote the intensity of use. Edilkamin and the retailer control and insert the 2 batteries in will not consider claims for battery life under any the indicated orientation.
Page 24
USER INSTRUCTIONS The display reads the POSSIBLE STATES described below: - OFF STATE The product is shutting down or is off in response to a manual switching off by using the ON/OFF button of the remote control or due to an external contact (crono, phone dialler) The display shows the current time, room temperature and the status in relation to which the product is OFF.
Page 25
USER INSTRUCTIONS USER CONTROLS (REMOTE CONTROL) Ventilation setting - ON/OFF Follow the instructions below to manually regulate the - Switch-on/switch-off power levels of the fan. - Manual mode setting Press “OK” once. • Power setting The fan setting displays, next to the blade symbol •...
Page 26
USER INSTRUCTIONS - Relax function - Stand by Natural convection function (without ventilation) with When the Stand by function is active, in automatic automatic power limiting. and crono modes, the product shuts off when the This function is available in all modes: automatic, temperature setpoint is reached and turns on again manual and crono.
Page 27
USER INSTRUCTIONS Crono The following screen will appear. Scroll to “ENABLE” When the Crono function is active, the user sets a (underlined) using the “+/-” buttons. temperature setpoint and a time zone for which that To enable the Crono function to 7 days a week or setpoint is specified.
Page 28
USER INSTRUCTIONS To combine one of the three temperatures To set the temperature setpoints (“TEMP” on to a time period (“SET” on the display), from the the display), from the Crono function, press the “OK” Crono function, press the “OK” button. The following button.
Page 29
USER INSTRUCTIONS The second screen (accessible by pressing the “OK” To view/change the settings (“CHANGE” on button from the first screen) allows you to set the start the display), from the Crono function, press the “OK” button. The following screen will appear. and end time of the time period matching the chosen Scroll to “CHANGE”...
Page 30
USER INSTRUCTIONS Night (deferred switching on/off) Load Pellets This function switches the product on/off after a set Allows you to load pellets after the screw feeder has emptied following a no-pellets alarm. period from activation of the function. Useful for the technician during commissioning. This is convenient if you go to bed and want the product Available only in the OFF state.
Page 31
USER INSTRUCTIONS Date/Time Beep Sets the current date/time. Allows you to enable/disable the beep. This displays the first time the remote control is To access the function from the main menu (as activated with the stove powered on, or by selecting indicated in the Menu section above), press the M the option in the menu.
MAINTENANCE Before doing any maintenance, disconnect the appliance from the mains. Regular maintenance is essential to keep the appliance in good working order. Failure to service the product properly will prevent it from working properly. Any problems due to failure to service the stove will void the warranty. DAILY MAINTENANCE These jobs should be done with the product off, cold and preferably disconnected from the mains.
Page 33
MAINTENANCE 1. Open the combustion chamber door (P) using the removable handle provided. 2. The burning pot (A) slips into position in its housing. Empty the ash tray(B) and burning pot into a non-flammable container (the ashes may still contain embers and/or hot parts) or vacuum if cold. Vacuum out the interior of the combustion chamber, the bed, and the compartment around the burning pot into which the ash falls.
Page 34
For any spare parts, contact your dealer or technician. flue every 3 months. Using non-original spare parts may damage the appliance and relieves Edilkamin of all liability for You should clean the chimney system at least once a damage resulting such use.
TROUBLESHOOTING If problems occur, the product shuts itself off automatically. The display will show the reason (see below). Do not disconnect from the power supply. To start the appliance up again, allow the shutdown procedure to complete, then press the ON/OFF button on the remote control or the simplified ignition button. Keep pressed till “UNLOCK ?”...
Page 36
TROUBLESHOOTING MESSAGE PROBLEM SOLUTION • Check the type of pellet (contact the technician if in Shut-down due to exceeding doubt) maximum fumes temperature. • contact the technician Switching OFF due to excessive • see HO7 overheating of the product. Shut-down due to gearmotor •...
Page 37
The battery symbol will appear on the remote control display if the battery is low. MAINTENANCE: A wrench symbol is shown on the display after 2000 hours of operation. The product is working, but it must be serviced by an authorised Edilkamin technician. USER/INSTALLER...
Page 40
*941833-GB* w w w . e d i l k a m i n . c o m code 941833-GB 09.18/H...
Need help?
Do you have a question about the VYDA AIR TIGHT and is the answer not in the manual?
Questions and answers