The Door Will Not Open - Miele WCE 330 Operating Instructions Manual

Hide thumbs Also See for WCE 330:
Table of Contents

Advertisement

Problem solving guide

The door will not open

Problem
The door cannot be
pulled open during a
programme.
Extra cooling
appears in the display
after a programme has
been cancelled.
The following appears
in the display:
 Service Door release
fault F35
60
Possible cause and remedy
The drum is locked during a programme.
 Touch the Start/Stop sensor to cancel the
programme.
The programme is cancelled, the door unlocks and
you can pull it open.
There is still water in the drum and the machine is
unable to drain.
 Clean the drain filter and the drain pump as
described in "Opening the door in the event of a
blocked drain outlet and/or power cut".
For safety reasons, the door cannot be opened if the
suds temperature is higher than 55°C.
 Wait until the temperature in the drum has
decreased and the message has gone out in the
display.
The door lock has jammed.
 Call Miele.