6. Screw fixing kit (with grille). meet the heat loss requirements of the room. ® l This MYSON KICKSPACE fan convector is designed for l Before proceeding with the installation, unpack the carton installation in the cavity beneath kitchen cupboards on the contents and check against the checklist below: vacant floor space, or other similar locations.
KICKSPACE ® 500 DUO ECO 2.0 Installation (continued...) ® l The unit should be mounted on a clean and level floor area l Replace the plinth and bring the KICKSPACE forward into under the cupboard base. the opening so the front edge projects approximately 10mm through the plinth.
KICKSPACE ® 500 DUO ECO 5.0 Waste Disposal According to the WEEE Directive (2012/19/EU) Waste disposal according to the WEEE Directive possible negative effects on the environment and health to which (2012/19/EU). The symbol on the product label the product can contribute if it is disposed of as ordinary domestic indicates that the product may not be handled as waste.
Page 5
KICKSPACE ® 500 DUO ECO 6.0 Controls (continued...) Operating Modes (continued...) Function Description Adjustment See previous page. Comfort Mode continued... Heating mode – Electric** To enter this mode: • Set the fan only/off/heating switch to heating (red dot) • Set the system selector switch to position II •...
Page 6
KICKSPACE ® 500 DUO ECO 6.0 Controls (continued...) Programme Mode A quantity of 9 built-in (P1-P9) and 4 user defined (U1-U4) timed Built-in Programme Selection programme options are available to choose from. Each day is 1. Select P by pressing until ‘ProG’...
Manually pair the thermostat to the receiver Press (OK) to begin pairing Myson Smart Start (Adaptive Start) Thermostat will learn to achieve temperature by time requested Window open detection, product will switch off if a large temperature drop is detected (usually caused by an open...
KICKSPACE ® 500 DUO ECO 8.0 Appendix Heating Performance Data Temperature Difference (°C) Model Heat Output (Watts) Heat Output (Btu/h) Speed ∆T20 ∆T30 ∆T40 ∆T50 ∆T60 ∆T20 ∆T30 ∆T40 ∆T50 ∆T60 Normal 1056 1340 1930 2501 3057 3603 500 DUO ECO Boost 1166 1412...
Page 9
KICKSPACE ® 500 DUO ECO 8.0 Appendix (continued...) Flexible pipes Heating Fan only / Off / Heating Blue System dot (B) / 0 / Red dot (R) Switch (B) (OFF) Electric / Hydronic System Selector Switch Isolating valves Boost / Normal Fan Speed Switch Fig.
KICKSPACE ® 500 DUO ECO 9.0 Eco Directive Characteristics Model identifier(s): KICKSPACE ® 500 DUO ECO Item Symbol Value Unit Item Unit Heat Output Type of heat input, for electric storage local space heaters only Nominal heat output P nom 1.03 manual heat charge control, with integrated thermostat N.A.
Page 12
Product code and serial number location Product Serial Number: COMPLETE HEATING SOLUTIONS...
Need help?
Do you have a question about the KICKSPACE 500 DUO ECO and is the answer not in the manual?
Questions and answers