ABB TPL65-A30 Operation Manual page 91

Hide thumbs Also See for TPL65-A30:
Table of Contents

Advertisement

Operation Manual / TPL65-A10 / -A30
8 Disassembly and assembly / 8.5 Removing cartridge group
© Copyright 2018 . All rights reserved.
Turn compressor casing (72000) together with wall insert and dif-
u
fuser and set them down with surface (F) on underlay.
WARNING
Tipping the compressor casing
Make sure that the underlay does not slip.
Allow compressor casing to rest only on surface (F).
u
Check the underlay and adjust it if necessary.
u
Remove the screw (72002).
u
Remove the diffuser (79000).
u
Carefully press off the wall insert (77000) using the press-off screws
u
(90900) and remove it using the swivel lifting eye (90230).
Remove the O-rings (77005 & 77006).
u
HZTL2482_EN