Fitting the filter silencer
Assemble the insert units (E) by inserting the absorption segments
u
(81136) into the sheet metal coverings (81137).
Bend sheet metal coverings (81137) back to original shape.
u
Insert the insert units (E) into slot guides in filter silencer unit (81135).
u
Install cover grids (81266) uniformly and in the correct position.
u
Push connecting rods (81269) through the lugs of cover grids (81266).
u
CAUTION
If connecting rods (81269) are not correctly positioned in their recesses
on filter silencer body (81135), cover grid (81266) can twist and shift.
There is then a risk of foreign matter and contamination getting into
the compressor.