Caimore CM520-86WG User Manual page 58

Mini 3g/4g wifi router
Table of Contents

Advertisement

Xiamen Caimore Communication Technology Co.,Ltd
2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009)
------------------------------------------------------------------------------
----------------------------------------
servers, please input the corresponding number.
 Center IP address and port:When there is only 1 center server, please input 1
in "center number", at this time, it only needs to configure "Main center IP and
port", inputting center server IP and port into corresponding bars, read picture
4-5-10. If center server doesn't use fixed IP address, but domain name, please
input domain name into corresponding IP address bar. Center 1 Address Port
~Center 4 Address Port don't need to input.
When there are several center servers (main number is more than 1), input
corresponding center server number in "center number", at this time, it needs to
configure "Center 1 Address Port" ~ "Center X Address Port", X is number of center
servers, input all center server IP address and port to corresponding bars, read picture
4-5-10. If center server doesn't use fixed IP address, but domain name, please input
domain name into corresponding IP address bar. In this time, "Main center IP
Address and Port" doesn't need to input.
 Protocol: set the working protocol. Default is CAIMORE DTU protocol. If
customers need their own protocol, please select CUSTOM option.
 Work Mode: Set transmission mode. There are TCP work mode and UDP work
mode. Default is TCP protocol.
 Baud rate:Setup working Baud rate of serial port, scope is 110~230400BPS.
Please set that baud rate is the same as that of user side equipment. Otherwise,
series port can't communicate.
 Data bits:Set working data bits of serial port, and the value can be 7 and 8.
Please set that data bits are the same as that of user side equipment. Otherwise,
series port can't communicate.
 Parity: Set the parity of serial port, and the values can be NONE, ODD or
EVEN. Please set that parity is the same as that of user side equipment.
Otherwise, series port can't communicate.
 Stop bits:Set stop bits of serial port, and the values can be 1 or 2. Please set
that stop bits are the same as that of user side equipment. Otherwise, series port
can't communicate.
 Device ID:number DTU, supplying one way of differentiating DTU for center
server. ID is fixed to be 8 numbers. If it is not full of 8 numbers, please add 0 in
front to make it full of 8 numbers.
 SIM Number: set mobile number which uses SIM card, and it is fixed to be
Tel:+86 592 5901215
58
web: en.caimore.com
58

Advertisement

Table of Contents
loading

Table of Contents