SkyZhone provides both Primary and Secondary lightning and surge
protection to the PoE cable. The Console cable is unprotected and should
not be install on the outdoor installations.
The National Electrical Code (NEC) and Canadian Electrical Code (CEC)
require the use of an agency listed (UL/CSA) Building Entrance Protector
for all power and data communications cables entering a building. This is to
protect the building and occupants from damage caused by transient
voltage and current surges.
A UL 497 (CSA C22.2 No. 226-92) approved primary protection device
must be used at the building entrance if the Ethernet port is used to provide
in-building access to the SkyZhone network. Also check with local wiring
codes.
Serious injury can occur if the antennas come in contact with electric power
lines. Carefully follow the instructions in this manual. During and after
installation, the antennas must be a minimum of 24 inches from any power
lines. Use caution when installing this outdoor equipment.
FCC RF Exposure Requirements (per OET-65) requires the SkyZhone
platform to be mounted such that the general public does not come within
10 inches of the antennae.
____________________________________________________________
Caution:
This product requires professional installation.
The unit is sealed at the factory and must not be opened in the field. The
unit shall be returned to the factory for repairs.
The PoE (Power over Ethernet) connector sources power to other devices.
Some devices may not be compatible with this feature. In that case, do not
connect the wires that supply the power. The power is 48 volts DC, at a
maximum of 5 watts.
____________________________________________________________
Note:
This equipment has been tested and found to comply with the limits for a
Class C digital device, pursuant to part 15, subpart C, of the FCC rules.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the user manual, may increase
the potential for harmful interference to radio communications.
This warning applies to the Skyzhone-1400 and SkyZhone-1600 only. This
equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if
SkyZhone 1600, 1400, 1200 Hardware Installation Guide