4.2.2 Detailed CD error code
Error
Focus serch error
Focus is not adjusted by
3-round focus serch
Tracking balance adjustment error
Time over(1s)
TOC area search error
Time over(10s)
Focus balance adjustment error
Time over(2s)
Focus gain adjustment error
Time over(0.6s)
Tracking gain adjustment error
Time over(0.6s)
TOC read error
Time over(30s)
1st track access error
Time over(10s)
Last track access error
Time over(10s)
Q code read error
Time over(0.6s)
TEXT data read error
RF read error
1-28 (No.MA048)
Details of error
When foucus is not adjusted by
3-round(1set) focus serch after
disc change or focus shock,
the result is NG
Tracking balance adjustment is
not finished 1s after adjustment
command(TBA) is executed
TOC area search is not finished
after 10s
Focus balance adjustment is
not finishied 2s after the adjustment
command(FBA) is executed
Foucus gain adjustment error is not
finished 0.6s after the adjustment
command(FGA) is executed
Tracking gain adjustment error
is not finished 0.6s after the
adjustment command(TGA) is
executed
TOC read operation is not
finished after 30s
1st track access is not finished
10s after TOC reading is finished
Last track access is not finished
10s after 1st track in running mode
Q code is not read for 0.6s during
playback of TOC and program
area
ALL TEXT data are not read
RF is not read
RFOK is recognized as L
Error code
Detailed error code
81H
0053
82H
0054
80H
0055
82H
0056
82H
0057
82H
0058
84H
0059
80H
0060
80H
0061
80H
0062
80H
0063
81H
0064

Advertisement