Installation Diagram; Indoor Unit; Outdoor Unit - Daikin FTD20JEV1K Installation Manual

R22 split series
Table of Contents

Advertisement

Indoor unit

Front panel
50mm or more from walls
(on both sides)
Titanium apatite photocatalytic
air-purifying lter (2)
Titanium apatite photocatalytic
air-purifying lter
Filter frame
Tab

Outdoor Unit

The outdoor unit must be installed in such a way, so as to
prevent short circuit of the hot discharged air or obstruction to
the smooth air flow. Please follow the installation clearances
shown in the figure. Select the coolest possible place where
intake air temperature is not greater than the outside air
temperature (please refer operating range).
Installation clearances
Dimension
Minimum Distance,
mm (in)
Note: If there is any obstacle higher than 2m, or if there is any
obstruction at the upper part of the unit, please allow more
space than the figure indicated in the above table.

INSTALLATION DIAGRAM

30mm or more from ceiling
M4 x 12L
Air lter
Opening service lid
Service lid is opening/
closing type.
Opening method
1) Remove the service lid
screws.
2) Pull out the service lid
diagonally down in the
direction of the arrow.
3) Pull down.
Air lter
INSTALLATION OF THE OUTDOOR UNIT
A
B
C
D
300
1000
300
500
(11.8)
(39.4)
(11.8)
(19.7)
Caulk pipe
hole gap
with putty.
Service lid
A
C
4
Cut thermal insulation pipe to
an appropriate length and wrap
it with tape, making sure that
no gap is left in the insulation
pipe's cut line.
Wrap the insulation pipe with the
nishing tape from bottom to top.
B
D