Operating And Non-Operating Conditions; Safety Characteristics; Power Supply For The Serveraid M5110 Sas/Sata Controller - Lenovo ServeRAID M5110 User Manual

Sas/sata controller
Hide thumbs Also See for ServeRAID M5110:
Table of Contents

Advertisement

3.3.5

Operating and Non-operating Conditions

3.3.6

Safety Characteristics

Table 3.6
Power Supply for the ServeRAID M5110 SAS/SATA
Controller
PCI Edge Connector
3.3V supply
+12V supply
3.3V auxiliary supply
The operating (thermal and atmospheric) conditions for the ServeRAID
M5110 SAS/SATA controller are:
Relative humidity range is 20 percent to 80 percent noncondensing
Airflow must be at least 200 linear feet per minute (LFPM) to avoid
operating the Intel IOP333 processor above the maximum
ambient temperature
Temperature range: +10 °C to +60 °C
The parameters for the non-operating (such as storage and transit)
environment for the controller are:
Relative humidity range is 5 percent to 90 percent noncondensing
Temperature range: −30 °C to +80 °C
The ServeRAID M5110 SAS/SATA controller meets or exceeds the
requirements of UL flammability rating 94 V0. Each bare board is also
marked with the supplier name or trademark, type, and UL flammability
rating. The board is installed in a PCI Express bus slot, so all voltages
are lower than the SELV 42.4 V limit.
Technical Specifications
State 1
State 2
0.1A
0.94762905A
0.84A
0.53350067A
0.76A
0.007135698A 0.0035464705A
State 3
0.94232971A
0.53209699A
3-9