Power Supply Requirements For The Serveraid M1115 Sas/Sata Controller; Operating And Non-Operating Conditions; Power Supply For The Serveraid M1115 Sas/Sata Controller - Lenovo ServeRAID M1115 User Manual

Sas/sata
Hide thumbs Also See for ServeRAID M1115:
Table of Contents

Advertisement

3.3.4
Power Supply Requirements for the ServeRAID M1115 SAS/SATA
Controller
3.3.5

Operating and Non-operating Conditions

3-6
All power is supplied to the controller through the PCI Express 3.3V rails
and the 12V rail. Onboard switching regulator circuitry operating from the
3.3V rails and the 12V rail provide the necessary voltages. The following
states determine the typical current consumption of the controller:
State 1: During a hard reset
State 2: During a disk stress test
State 3: While sitting idle at the DOS prompt
The supply voltages are 12V ± 8 percent (from PCI edge connector only)
and 3.3V ± - 9 percent (from PCI edge connector only).
the power supply for the controller for each of the three states at the
different voltages.
Table 3.6
Power Supply for the ServeRAID M1115 SAS/SATA
Controller
PCI Edge Connector
3.3V supply
+12V supply
3.3V auxiliary supply
The operating (thermal and atmospheric) conditions for the ServeRAID
M1115 SAS/SATA controller are:
Relative humidity range is 20 percent to 80 percent noncondensing
Airflow must be at least 200 linear feet per minute (LFPM) to avoid
operating the Intel IOP333 processor above the maximum
ambient temperature
Temperature range: +10 °C to +60 °C
The parameters for the non-operating (such as storage and transit)
environment for the controller are:
ServeRAID M1115 SAS/SATA Controller Characteristics
State 1
State 2
330mA
330mA
1.00A
1.81A
30mA
30mA
Table 3.6
lists
State 3
330mA
1.53A
30mA

Hide quick links:

Advertisement

Table of Contents
loading