Finishing; Fastener Placement Restriction - Napoleon L38N Installation Manual

Acies series
Hide thumbs Also See for L38N:
Table of Contents

Advertisement

Available languages

Available languages

11.0 finishing

WARNING
!
Risk of fire!
Never obstruct the front opening of the appliance.
The front of the appliance must be finished with non-combustible materials such as brick, marble, granite, etc.,
provided that these materials do not go below the specified dimension.
Do not strike, slam, or scratch.
Do not operate appliance with glass removed, cracked, or scratched.
Facing and/or finishing material must never overhang into the appliance opening (i.e. must never encroach inside
finishing flange).
The glass door assembly is designed to pivot forward when relieving excess pressure that might occur. Finishing
or other materials must not be located in the opening surrounding the door as this will interfere with the doors
ability to relieve pressure.

11.1 fastener placement restriction

No fasteners permitted.
No fasteners permitted with greater than 3/4"
penetration into appliance.
When securing non-combustibles, we suggest using high temperature construction adhesive within 2" (5.08cm)
above and to the sides from the appliance opening and 8" (20.3cm) below the appliance opening. DO NOT
SCREW IN THE RESTRICTED AREA AS THIS COULD DAMAGE THE INTERNAL COMPONENTS OF THE
APPLIANCE THAT CAN CAUSE INJURY OR DEATH.
This applies to both single-sided and see-thru appliances.
Maximum screw length to be used outside the restricted screw area is 3/4" greater than finishing material
thickness.(i.e. no fastener permitted that penetrates the appliance more than 3/4"
2"
1 1/2"
6"
8"
finishing