Before framing your appliance, determine vent requirements before deciding the final location of the appliance.
After rough framing, place the appliance in its final position.
single-sided
J
minimum framing
Ref
E
F
J
*L
see-thru
minimum framing
Ref
E
16 3/16" (41.1cm)
53 13/16" (136.7cm)
F
J
Optional - Appliance does not need to be elevated above floor
74" (188cm)
*L
rough framing - before appliance installation
L
E
F
L38
18" (45.7cm)
53 13/16" (136.7cm)
Optional - Appliance does not need to be elevated above floor
74" (188cm)
L
E
F
J
L38
Before framing the appliance, ensure to install the
firestop first as it will not fit between the studs if
installed after framing.
L50
18" (45.7cm)
65 13/16" (167.2cm)
74" (188cm)
Before framing the appliance, ensure to install the
firestop first as it will not fit between the studs if
installed after framing.
L50
16 3/16" (41.1cm)
65 13/16" (167.2cm)
74" (188cm)
*Minimum enclosure
height maybe higher de-
pending on venting con-
figuration (See minimum
distance to combustibles
W415-1707 / 07.04.17