How To Reset To Factory Default Settings - Axis P3707-PE User Manual

Table of Contents

Advertisement

AXIS P3707-PE Network Camera
About system options
File Upload
Files, for example webpages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go
to System Options > Advanced > File Upload.
Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the
selected user group (viewer, operator or administrator) for the uploaded file.
Plain Config
Plain Config is for advanced users with experience of Axis product configuration. Most parameters can be set and modified from
this page.
To open Plain Config, go to System Options > Advanced > Plain Config. Axis Support does not provide assistance with this feature.

How to reset to factory default settings

Important
Reset to factory default should be used with caution. A reset to factory default resets all settings, including the IP address, to
the factory default values.
Note
For products with multiple IP addresses channel 1 will have the address 192.168.0.90, channel 2 will have the address
192.168.0.91 and so on.
To reset the product to the factory default settings:
1. Press and hold the control button and the restart button at the same time.
2. Release the restart button but continue to hold down the control button for 15–30 seconds until the status LED indicator
flashes amber.
3. Release the control button. The process is complete when the status LED indicator turns green. The product has been reset
to the factory default settings. If no DHCP server is available on the network, the default IP address is 192.168.0.90
4. Using the installation and management software tools, assign an IP address, set the password and access the video stream
It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance and
click Default.