Shock Sensor Harness, 4-Pin Connector - Directed Electronics Python 1500 esp Installation Manual

Car alarm system and remote start
Hide thumbs Also See for Python 1500 esp:
Table of Contents

Advertisement

shock sensor harness, 4-pin connector

GREEN (-) multiplex input, zone 2
Inputs shorter than 0.8 seconds will trigger the Warn Away® response, while inputs longer than 0.8 seconds will
trigger full alarm sequence and report Zone Two. If installing an optional DEI® dual stage sensor, connect to the
green wire as shown below. The diagram below eliminates the need for diodes to isolate the sensors.
Diagram for adding optional DEI® dual stage sensor to green wire (Zone 2):
BLUE (-) multiplex input, zone 2
Inputs shorter than 0.8 seconds will trigger the Warn Away® response, while inputs longer than 0.8 seconds will
trigger full alarm sequence and will also report Zone Two.
RED and BLACK: RED is (+)12V constant, BLACK is (-) ground
Do not use these for anything besides the plug-in shock sensor.