TANKLESS GAS WATER HEATER
Potential dangers from accidents during installation and use are divided into the following three
categories. Closely observe these warnings, they are critical to your safety.
DANGER
WARNING
CAUTION
WARNING:
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
Prohibited
Requests to Installers
• In order to use the water heater safely, read this installation manual carefully, and follow the
installation instructions.
• Failures and damage caused by erroneous work or work not as instructed in this manual are not
covered by the warranty.
• Check that the installation was done properly in accordance with this Installation Manual upon
completion.
• After completing installation, please either place this Installation Manual in a plastic pouch and
attach it to the side of the water heater (or the inside of the pipe cover or recess box if applicable),
or hand it to the customer to retain for future reference. Also, be sure to fill in all of the required
items on the warranty and to hand the warranty to the customer along with the Owner's Guide.
CERTIFIED
R
SBA8375
Rev. 09/09
NR111-OD
DANGER indicates an imminently hazardous situation which,
if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury.
Disconnect
Power
Low NOx
Approved by
SCAQMD
Accepted For Use
City of New York
Department of Buildings
MEA 19-03-E
(Outdoor Installation)
Ground
CAUTION
FOR USE IN RESIDENTIAL, COMMERCIAL, OR MANUFACTURED
HOME APPLICATIONS.
Installation must conform with local codes, or in the absence of local codes,
the National Fuel Gas Code, ANSI Z223.1/NFPA 54- latest edition and/or CSA
B149.1, Natural Gas and Propane Installation Code (NSCNGPIC).
When applicable, installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280 or the
Canadian Standard CAN/CSA-Z240 MH Mobile Homes, Series M86.
Noritz America reserves the right to discontinue, or change at any
time, the designs and/or specifications of its products without notice.
NORITZ AMERICA
CORPORATION
Be sure to do
*SBA8375*

Advertisement

Table of Contents
loading

Summary of Contents for Noritz NR111-OD

  • Page 1 Home Construction and Safety Standard, Title 24 CFR, Part 3280 or the Approved by Canadian Standard CAN/CSA-Z240 MH Mobile Homes, Series M86. SCAQMD Noritz America reserves the right to discontinue, or change at any time, the designs and/or specifications of its products without notice. Accepted For Use City of New York...
  • Page 2: Included Accessories

    The following accessories are included with the unit. Included Accessories Check for any missing items before starting installation. Part Shape Part Shape Q’ty Q’ty Owner's Guide, Warranty, Cross Recessed Installation Manual Head Screw each (this document) Remote Controller Remote Controller (See p.
  • Page 3: Quick Connect Multi System Installation

    Quick Connect Multi System Installation • The Quick Connect Multi System allows the installation of two units together utilizing only the Quick Connect Cord. The Quick Connect Cord is 6 ft. long. Install the units 2-19" apart from each other to ensure the cord will be able to reach between the units.
  • Page 4: Before Installation

    Before Installation WARNING Check the Gas • Check that the rating plate indicates the NR111-OD correct type of gas. 250,000 BTU 11,000 BTU • Check that the gas supply line is sized for 10.5 0.70 2.75 250,000 Btuh for this unit.
  • Page 5 WARNING • Avoid places where fires are common, such as those where gasoline, benzene and adhesives are handled, or places in which corrosive gases (ammonia, chlorine, sulfur, ethylene compounds, acids) are present. Prohibited Using the incorrect voltage may result in fire or cracking. •...
  • Page 6: Installation Clearances

    Installation Clearances WARNING Before installing, check for the following: Install in accordance with relevant building and mechanical codes, as well as any local, state or national regulations, or in the absence of local and state codes, to the National Fuel Gas Code ANSI Z223.1/NFPA 54 –...
  • Page 7 Clearance Requirements from Vent Terminations to Building Openings * All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC. Vent Terminal Area Where Terminal is Not Permitted Air Supply Inlet Outdoor Installation Clearance...
  • Page 8 Clearance Requirements from Vent Terminations to Building Openings * All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC. Maintain the following clearances to any Illustration opening in any building: •...
  • Page 9: Installation

    Installation Securing to the wall • The weight of the device will be applied to the wall. If the strength of the wall is not suffi- cient, reinforcement must be done to prevent the transfer of vibration. • Do not drop or apply unnecessary force to the device when installing. Internal parts may be damaged and may become highly dangerous.
  • Page 10: Gas Piping

    1/8" NPT screw with an allen wrench and connecting the appropriate pressure gauge. Instructions Sample Gas Line 1. Size each outlet branch starting from the furthest Noritz NR111-OD using the Btuh required and the length from the Barbecue (250,000 Btuh) meter. (50,000 Btuh) Outlet E 2.
  • Page 11 Gas Line Sizing for a Noritz NR111-OD Adapted from UPC 1997 Maximum Natur Natural Gas Delivery Capacity in Cubic Feet per Hour (0.60 Specific Gravity, 0.5" WC Pressure Drop) Length in Feet Pipe 100' 125' Size 1/2" 3/4" 1" 1 1/4"...
  • Page 12: Water Piping

    Installation and service must be performed by a qualified plumber. In the Water Piping Commonwealth of Massachusetts, this product must be installed by a licensed plumber or gas fitter in accordance with the Massachusetts Plumbing and Fuel Gas Code 248 CMR Sections 2.00 and 5.00. Observe all applicable codes. This appliance is suitable for potable water and space heating applications.
  • Page 13 Supply water piping Hot water piping • Do not use PVC, iron, or any piping which has been • Do not use lead, PVC, iron or any piping which treated with chromates, boiler seal or other chemicals. has been treated with chromates, boiler seal or •...
  • Page 14: Water Treatment

    Noritz Scale Shield, that reduce the amount of scale deposits. Refer to the below tables for sug- gested treatment and maintenance measures to be taken based on the water hardness level. Damage to the water heater as a result of water in excess of 12 gpg (200 mg/L) of hardness is not covered by the Noritz America Limited Warranty.
  • Page 15: Plumbing Applications

    (Model L6006A or L6006C) Combination Potable Water and Space Heating System Notes: 1. Noritz recommends the use of an Isolation Kit with the installation. These kits include an integrated shut-off and serv- ice valve with unions and a pressure relief valve.
  • Page 16: Electrical Wiring

    Consult a qualified electrician Electrical Wiring for the electrical work. Do not connect electrical power to the unit until all electrical wiring has been completed. Disconnect Power This appliance must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.
  • Page 17: Remote Controller

    To keep the water heater off, let the unit sit for 30 sec. to return to the original display. • The NR111-OD can be programmed so that it will default to one of four temperatures if the remote control- ler is removed (180, 140, 130, 120°F). To change the default temperature, connect the temperature selection wire as shown in the above diagram.
  • Page 18 Connecting Remote Controller Cord to Unit • Keep the remote controller cord away from the freeze prevention heaters in the unit. • Tie the redundant cord outside the water heater. Do not put the extra length inside the equipment. • The remote controller cord can be extended up to 300' with 18AWG wire. •...
  • Page 19: Pump Wiring

    * This feature is not available when using the Quick Con- Pump Wiring nect Multi System feature. Connecting the pump control wire 1. Leave enough slack so that the pump control wires will stay connected if the unit is removed Pump Control from the wall.
  • Page 20 For Quick Connect Multi System Installation Connecting Quick Connect Cord usa a Quick Connect Cord (sold separately). Caution The wire coloring on the Quick Connect Cord will not be the same as the wire coloring of the connection plug inside the unit. 1.Red 1.Red 1.White...
  • Page 21: Maintenance

    Periodically check the following to ensure proper Maintenance operation of the water heater. • The venting system must be examined periodically by a qualified service technician to check for any leaks or corrosion. • The burner flame must be checked periodically for a proper blue color and consistency. •...
  • Page 22: Lighting Instructions

    CAUTION Handling after trial operation • If the unit will not be used immediately, close off all gas and water shutoff valves, drain all of the water out of the unit and the plumbing system to prevent the unit and system from freezing, and bleed the gas out of the gas line.
  • Page 23 Dimensions NR111-OD 17.7" < inch > 4- 0.5" 6 - 0.24 x 0.4" OBLONG HOLE 6.7" 5.5" 18.3" 3.9" 2.8" 17.6" 1.4" 10.6" 3.2" 0.4" 9.4" 0.4" FLUE COLLAR AIR INLET AIR INLET 0.4" 1.4" 2.8" 3.9" COLD WATER INLET WIRING THROUGHWAYS 5.5"...
  • Page 24 Remote Controller RC-7649M carefully before carrying out installation. Installation Guide NORITZ AMERICA CORPORATION Note Do not connect power to the water heater before the remote controller has been properly installed. Recommended installation location of the remote controller is in a bathroom.
  • Page 25 Installation 3. Remove the cover of the remote control, 1. Apply Wall Packing to the rear side of the mark the location of the screw holes, and remote controller. drill holes for the wall anchors. 2. Connect the remote controller wires to the 4.
  • Page 26 Installing the Remote Controller Outdoor Junction Box 5. Slide the box nut over the remote controller 1. Insert the remote controller wires through the wires and screw it onto the wall pipe. wall pipe and secure the wall pipe to the remote controller.

Table of Contents