Bosch HMV 8051 U Installation Instructions Manual page 4

Hide thumbs Also See for HMV 8051 U:
Table of Contents

Advertisement

Available languages

Available languages

Important Safety Instructions
READ AND SAVE THESE INSTRUCTIONS
Electrical
Requirements
÷ a three prong grounded outlet
÷ 120 V, 60 Hz, AC only
÷ 15 Amp electrical supply with a fuse or a circiut breaker
÷ 1.6 kilowatt
This product must be connected to a supply circiut of the proper voltage and
frequency. Wire size must conform to the requirements of the National Electric Code
or the prevailing local code for this rating. The power supply cord and plug should
be brought to a separate 15- to 20-amp branch circiut single grounded outlet. The
outlet box should be located in the cabinet above the microwave oven. The outlet
box and supply circiut should be installed by a qualified electrician and conform to
the National Electrical Code or the prevailing local code.
The voltage used must be the same as specified on this microwave oven. Using a
higher voltage is dangerous and may result in a fire or oven damage. Using a lower
voltage will cause slow cooking. The dealer is not responsible for any damages
resulting from the use of the oven with any voltage other than specified.
Location
requirements
Check the opening where the microwave oven will be installed. The location must
provide:
÷ Minimum installation dimensions
(See Installation
Dimensions
illustration)
÷ Minimum one 2" x 4" (50.8 x 101.6 mm) wood wall stud and minimum 3/8" (9.5
mm) thickness drywall or plaster/lath within cabinet opening.
÷ Support for weight of 150 Ibs (68 kg), which includes microwave oven and items
placed inside the microwave oven and upper cabinet.
÷ Grounded electrical outlet inside upper cabinet. (See Electrical
Requirements)
section.
Notes:
If installing the microwave oven near a left sidewall, make sure there is at least 7"
(178 mm) of clearance between the wall and the microwave oven, so that the
door can open fully.
Some cabinet and building materials are not designed to withstand the heat
produced by the microwave oven for cooking. Check with your builder or cabinet
supplier to make sure that the materials used will not discolor, delaminate or
sustain other damages.
Ground continuity
check
The installer must perform a ground continuity check on the power outlet box before
beginning the installation to insure that the outlet box is properly grounded. If not
properly grounded, or if the outlet box does not meet Electrical
Requirements,
a
qualified electrician should be employed to correct any deficiencies.