6. Operation

6.1 Preparation steps

6.1.1 Use of protective equipment

DANGER
• Welding operations in narrow spaces may cause asphyxia due to lack of oxygen.
• Prepare ventilation facilities to prevent the inhalation of gases and fumes generated during the welding
operation. Otherwise, wear a respirator.
CAUTION
• Wear leather gloves and safety shoes to protect the exposed parts of your
eyes and skin.
• Prepare light-shielding glasses or a welding face-shield with a light-shield-
ing filter plate appropriate to the applied welding current.
• Prepare the ear protection device.

6.1.2 Confirmation of completed connection

Check to confirm the following connections
- Connections to input power unit and grounding wire.
- Connections to base metal, welding torch and of gas.

6.1.3 Turning ON power

(1) Turn on the switch of the distribution box.
(2) Turn on the "POWER" switch. (The set-value display
and the LCD display on the front panel are turned on.)

6.1.4 Adjusting gas flow rate

(1) Place the "GAS" switch to the "PURGE" position.
(2) Open the main valve of the gas cylinder. (Make sure
that the flow adjustment knob is at the side of [SHUT]
before opening the main switch.)
(3) Turn the flow adjustment knob in the direction of
[OPEN], and adjust it until the flow meter indicates the
required value.
(4) On completion of the flow rate, set the "GAS" switch
to the "WELD" position.
OMCTT5639E09
To protect you and other people from gases, fumes and lack of oxygen that may
be generated during the welding operation, make sure to prepare ventilation facil-
ities and use protective equipment, etc.
To protect you and other people from arc light, fly-
ing spatters, slag, and arc noises generated by
welding, use protective equipment.
(See sections "Configuration" and "Connection."
Operation
"POWER" switch
"GAS" switch
Gas cylinder
main valve
Flow adjustment knob