Troubleshooting Table - Panasonic YC-300BP2YAF Operating Instructions Manual

Inverter tig welding power source
Table of Contents

Advertisement

Troubleshooting

8.2 Troubleshooting table

* In the case of welding errors without any error (Err) indication, refer to the following table to search for their causes.
Front panel display is not turned on
Error
Neither high frequency wave nor arc is gener-
condition
ated.
High frequency wave is generated without arc.
Bead turns black.
Lack of arc occurs.
Insufficient arc start
No gas supply
Gas flows without stop
Check item
Distribution box
(Input protection device)
Input cable
Switches
Gas cylinder and
Gas regulator
Gas hose (From gas cylin-
der to torch.)
Torch cable
Around the torch body
Cables on the base metal
Welding conditions
Factory settings
48
Probable causes
• Switch is not ON.
• Blown fuse.
• Tripping of circuit breaker.
• Loose connections.
• Cable is disconnected or severed.
• Loose connections.
• No phase.
• Switch is not ON.
• "GAS" switch is placed to "Purge".
• Main cock is not open.
• Gas nearly runs short.
• Insufficient flow rate.
• Excessive flow rate.
• Loose connections
• Hose is damaged.
• Torch is bent at acute angle.
• Coating is damaged.
• Sign of insulation deterioration.
• Torch switch is not ON.
• Insufficient fastening of the collet.
• Sizes of collet body, collet and electrode
do not match.
• Insufficient fastening of the torch body.
• Attach an earth ring ass'y.
• Insufficient cable size (sectional area.)
• Loose connections
• Poorly energized base metal.
• Check torch angle, distance between
electrode and base metal once again.
• Try to set "Hot Cur Level" to "High"
• Try to set "AR Arc Recovery" to "ON".
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
OMCTT5639E09