Connection
5.6 Connecting with external device connecting unit
5.6.1 Applications
To switch the pages of stored welding conditions by connect-
ing external equipment (sequencer) to the product.
(For details, see manual of the external device connecting
unit.)
5.6.2 Connection
• Draw harnesses or cables from the connecting unit via
this wire port(d). (*Loosen four crews (a) and two eye-
bolts (b) and then remove the top panel (c).
• To enable the function of the connecting unit, make sure
to turn ON the DIP switch DSW2 #10.
(When not using the function of communication, turn it off
again.)
30
Note
For preventing troubles caused by incorporation of the
high frequency wave, see "Installation: Peripheral equip-
ment".
a
b
c
200 V harness
(*)
Line from the
connecting unit
e
(*)
: [CN1] is for an external device.
e
Rear
d
Front
OMCTT5639E09