8. Various settings

8.6 Group3: SYSTEM settings

8.6.1 Setting items

* Submenu numbers not in use are ignored.
Dial 1
ENTER button
Contents
Crater repeat ON/OFF
Leg length control ON/OFF
(To keep the leg length con-
stance regardless of change
of wire extension.)
Wire extension (mm)
(Except semi-auto welding,
welding table is selected
based on the wire extension.)
Analog remote controller
With/Without
CALL/RECORD function ON/
OFF
Max. voltage for current/
voltage preset value of
remote controller set value
(V)
Output limit (A)
(Setting the max. output cur-
rent)
Energy saving (Specify a
standby time for all LED to be
turned off. (minute)
Guide LCD ON/OFF
(Whether to turn OFF the
backlight if there is no item
to display on LCD.
Start circuit With/Without
Output value correction: GAIN (%)
104
Indicates set value
Dial 2
Submenu#
LCD display (1st line)
00
CRATER REP
01
LEG LENGTH CTRL
02
WIRE EXT. LENGTH
03
ANALOG RC
(*)
04
PLY/REC USE SEL.
05
INPUT VOLTAGE
06
OUTPUT CONTROL
07
ENERGY SAVING
08
GUIDE LCD CTRL.
09
START CIRCUIT
10
GAIN
Panasonic
VP1 series
0: OFF
1: ON
0: OFF
1: ON
0: Semi-auto welding
1: 10 mm
2: 12 mm
3: 15 mm
4: 20 mm
5: 25 mm
0: Without
1: With
0: OFF
1: ON
0: 15 V
1: 12 V
2: 10 V
to
30
to
0
0: ON (to turn off back-
light)
1: OFF (Keep the back-
light ON all the time.)
0: Without
1: With
80 to 120
Submenu number
・Use Dial1 to select.
・Press ENTER to set.
Set value
・Use Dial2 to select.
・Press ENTER to set.
Incre-
Setting range
ment
400
10
1
10
1
WMD078TE0PAA07
Default
0
0
0
1
1
0
400
0
0
1
100