Siemens SIMATIC RTLS4330G Operating Instructions Manual page 18

Localization systems
Hide thumbs Also See for SIMATIC RTLS4330G:
Table of Contents

Advertisement

Installation & Operation
3.1 Notes on installation
Connection of the cables
Make sure that the Twist-Lock connectors are inserted correctly to prevent moisture from
entering the enclosure.
Make sure that the wiring is correct before you start up the device.
Only use the cables described in the order data, supplied with the device or otherwise
prescribed. Siemens AG is not liable for damage or functional limitations caused by the use of
other cables.
Protect the device from penetrating moisture by closing off connectors that are not in use
with suitable covers. These covers are installed on the device.
Supply voltage
When the supply voltage is connected to the power plug, all LEDs flash briefly for a moment.
The RUN LED lights up as soon as voltage is present.
You can supply the device with power via the Ethernet cable. In this case, the power plug
must be tightly sealed to prevent moisture from penetrating. The device is a class 0 device
according to PoE.
NOTICE
No simultaneous power supply
Do not supply the device with power through the mains and the PoE connection at the same
time.
Check whether the rated voltage of the power supply corresponds to the values in the section
"Technical specifications (Page 23)".