SINGLE-PACKAGE
ELECTRIC HEATING
COOLING UNITS
HRVBBLHU
HRVBBSVC
HRVBBLVU
The Heat Recovery Ventilation (HRV) system offered by Bryant
is the finest unit on the market today.
The HRVB provides efficient and cost-effective heat recovery
during the heating season when needed most.
As temperatures drop below 23°F (–5°C), indoor air is
recirculated periodically through the heat exchanger core to
prevent frost from forming. Competitors' methods of
supplementary electric defrost waste energy. Unlike rotary
wheel heat exchangers which mix air streams, these cross flow
or counterflow heat exchangers ensure that there is no mixing
of the stale air stream with the fresh outdoor air stream.
A filter installed on the incoming outdoor air stream removes
large airborne particles from the intake air stream before they
enter the heat exchanger and reduces the maintenance
required.
The units' acoustically engineered design makes them the
quietest on the market and ensures that comfort is felt, not
heard.
Unlatching 2 suitcase style latches allows easy removal of the
filters and core for cleaning.
FEATURES
• Energy saving defrost cycle
• Cross flow, counterflow heat exchangers
• Two filters on incoming outdoor air stream to protect the HRV
core
• Acoustical design
• No-tools maintenance
• Polypropylene heat exchanger core
HRVBBLHU
HRVBBSVC
HRVBBLVU
Heat Recovery Ventilators
Form No. PDS HRV.71.1

Advertisement

Table of Contents
loading

Summary of Contents for Bryant HRVBBLHU

  • Page 1 COOLING UNITS HRVBBLHU HRVBBSVC HRVBBLVU The Heat Recovery Ventilation (HRV) system offered by Bryant is the finest unit on the market today. The HRVB provides efficient and cost-effective heat recovery during the heating season when needed most. As temperatures drop below 23°F (–5°C), indoor air is recirculated periodically through the heat exchanger core to prevent frost from forming.
  • Page 2: Model Number Nomenclature

    Model number nomenclature Brand: Bryant Equipment Type: Heat Recovery Ventilator Climate Map for Energy and Heat Recovery Ventilators Edmonton Vancouver Helena Salem Boise Sacramento Salt Lake City Honolulu HRV Recommended ERV Recommended w/HRV or ERV Wall Control ERV Recommended Electrical Supply: 1 —...
  • Page 3 At start up, when 7 in. duct work is connected to HRV At start up, when 8 in. duct work is connected to HRV Used with HRVBBLHU 1150 Unit 11 3/4 x 12 7/8 x 3/4 (2) Used with HRVBBLHU 1250 Unit 11 3/4 x 16 3/4 x 3/4 (2)
  • Page 4: Control Features

    This allows warm indoor air to recirculate within the heat recovery core. The frequency of this cycle increases as the outside air temperature decreases. 23°F TO 55°F (–5°C TO –15°C) MODEL DEFROST* HRVBBLHU 6 Minutes HRVBBSVU 6 Minutes HRVBBLVU...
  • Page 5 —5—...
  • Page 6 —6—...
  • Page 7 —7—...
  • Page 8: Physical Data

    MODEL DESCRIPTION CONVENTIONAL Model No. HRVBBVHU1150 HRVBBVHU1260 HRVBBSVC1150 HRVBBSVC1200 HRUBBLVU1150 HRUBBLVU1200 HRUBBLVU1330 Port Locations Sides Core Type Polypropylene Cross Flow Weight — lb (kg) 65 (29.5) Shipping Weight — lb (kg) 75 (34) Shipping Dimensions (in.) Height 23 1/16 Width 36 1/16 Depth 17 13/16...
  • Page 9 METHOD 1 1. Calculate cu ft of occupied space. 2. Multiply by recommended air changes per hr (AC/h). 3. Divide by 60 minutes per hr to convert to CFM. EXAMPLE: 2000 sq ft with 8 ft ceiling 0.35 air changes per hr (AC/h) (2000 sq ft x 8 ft ceiling x 0.35 AC/h) / 60 min/h = 93.3 CFM METHOD 2 1.
  • Page 10 Outside Enthalpy Btu/lb HRVBBLHU1150 HRVBBLHU1250 HRVBBSVC1150 HRVBBSVC1200 HRVBBLVU1150 1,090 1,509 1,928 2,347 2,766 3,185 3,604 4,023 4,442 4,861 5,280 5,699 The cooling load chart shows loads in Btuh as well. To use the cooling load chart, first find the design enthalpy from a psychrometric chart using the design dry bulb and wet bulb temperatures.
  • Page 11 —11—...
  • Page 12 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: New FORM PDS HRV.71.1 © 2000 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231 PRINTED IN U.S.A. Catalog No. 12HR-VBO 3-00 —12—...

This manual is also suitable for:

HrvbblvuHrvbbsvc

Table of Contents