WeatherTRAK ET Pro3 Quick Reference Card

Hide thumbs Also See for ET Pro3:

Advertisement

Available languages

Available languages

BASIC TASKS

ACTIVATE

Access this controller from WeatherTRAK.net or
WeatherTRAK Mobile
• Call Customer Support at: 800.362.8774
• Fill out the activation form at: hydropoint.com/activate

SET CONTROLLER MODE

Controller On/Off, Shutdown, or Winterized
• Press
button
• Use
button to select desired function
• To clear Shutdown or Winterized, press
Button, then press
to reset the status

SITE CHECK

Manual Operation / Wet Check
• Use "Manual" Feature on WeatherTRAK Mobile
• Press Manual Test button. Then select:
• By Station to operate a single station
• All Stations to operate all stations sequentially
• By Program to operate all stations assigned
to the same program

ADJUST

Landscape too wet or too dry
• Use "% Adjust" Feature on WeatherTRAK Mobile
• Press Adjust button:
• Use
button to select desired station
• Use
or
buttons to make desired
adjustments

ALERT MANAGEMENT

MOBILE APP
Go to the
tab on the Controller Settings page.
WEB
Use Alerts Page, or Multi-Controller Alert Report from
weathertrak.net.
CONTROLLER
While at the controller, use the following process:
Press
Button. The first screen is the
showing any alert or warning that exists
on your controller. Each two letter code is an Alert
Category. An
or
appear beneath any category
that has an alert present.
:
Flow Alerts — Issue with flow hardware or flow
feature programming. Fix the issue, then press
button to clear alert then retest
Valve Alerts — Issue with valve electrical
:
components or connections. Fix the issue, then
press
button to clear alert then retest
Communication Alerts — Reset GPRS Status or
:
call Customer Service for assistance
:
Water Window Warning — Calculated irrigation
schedule exceeds the allowable irrigation time
programmed Water Window
Water Day Warning — Calculated irrigation
:
schedule exceeds number of allowable Water Days
programmed in Water Day Mode
Station High Depletion — Reset Station
:
Depletion from Manage Page of weathertrak.net or
from Help menu — "Help : 12 — Current Depletion"
:
Hardware Alert — Issue with controller hardware.
Call Customer Service for assistance
Subscription Alert — Call Customer Service to
:
update data service plan
QUICK REFERENCE CARD

TROUBLESHOOTING

If you suspect that there is an issue with your
WeatherTRAK Controller hardware, we have easy to use
LED diagnostic lights on the controller chassis.
Remove the controller panel from its mounted to position
to completely reveal the controller chassis.
Use the chassis diagram above to identify each of the
six LED Diagnostic lights on the chassis and check to
see if each is illuminated. Then, compare result to the
diagnostic table and take appropriate action.
Contact Customer Support with any questions:
800.362.8774 or support@hydropoint.com.
FL1
VC
MV1
VC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ET Pro3 and is the answer not in the manual?

Questions and answers

Summary of Contents for WeatherTRAK ET Pro3

  • Page 1 If you suspect that there is an issue with your • Use “Manual” Feature on WeatherTRAK Mobile schedule exceeds the allowable irrigation time WeatherTRAK Controller hardware, we have easy to use • Press Manual Test button. Then select: programmed Water Window LED diagnostic lights on the controller chassis.
  • Page 2 Depleción Desde la página de administración en Utilice el diagrama de chasis que se muestra arriba, para AJUSTE weathertrak.net o desde el menú de ayuda — ”Help:12 — identificar cada una de las seis diagnóstico luces de LED en Paisaje demasiado húmedo o demasiado seco Current Depletion”...

Table of Contents