TROUBLESHOOTING / FELSÖKNING
SYMPTOM
POSSIBLE FAULT
No or low air pressure.
Faulty air motor.
Pump stationary, or
Blocked air inlet filter
runs very slowly
Ice blocking air exhaust
Foreign object jamming the movement of the central
bar.
No fluid
Pump reciprocating but
Foot valve inoperative.
not delivering fluid.
Piston valve or seals worn out.
Oil is coming out of the
Packing between air motor and pump is worn out or
"leakage" hole in the
damaged.
outlet body
Packing on the lower piston assembly is worn out or
Pump is running
damaged.
despite the outlet being
Dirt in the bottom valve or in the lower piston assem-
closed
bly.
SYMPTOM
TROLIG ORSAK
Ej tillräckligt lufftryck.
Trasig luftmotor.
Pumpen går ej eller
Blockerat luftfilter.
ingen vätska kommer.
Isbildning i ljuddämpare.
Främmande föremål blockerar centralstångens
rörelse.
Ingen vätska
Pumpen går men
Bottenventil ej tät.
levererar ingen vätska.
Kolv eller kolvtätningar utslitna.
Olja läcker ut genom
Tätningar mellan luftmotor och vätskedel är utslitna
läckagehål i pumphus.
eller skadade.
Luft läcker ut genom
Tätning i nedre kolv är utsliten eller skadad.
ljuddämpare när
Smuts i bottenventil eller nedre kolv.
pumpen står still.
Alentec & Orion AB Grustagsvägen 4, SE-13840, Älta, SWEDEN · info@alentec.se · www.alentec.com
8
SOLUTION
Check the air line valve, regulator and quick coupler.
Check air motor mechanism. Check seals as required and
replace any faulty parts.
Change or clean the air inlet filter
Inspect for possible condensate in air filter or, if the pump
has "raced", that there is no leakage in the pipe work.
As above. Check for free movement and for foreign objects
in piston valve etc.
Check fluid level in drum/tank in relation to riser tube/outlet
point.
Check spring and valve for correct operation and seating.
Check for foreign objects jammed in foot valve.
Check for foreign objects in piston valve seat. Check seals
for wear and damage.
See "Service, exchange of packings between air motor and
pump tube".
See "Service to pump mechanism".
See "Service to pump mechanism".
ÅTGÄRD
Kontrollera luftventil, regulator och snabbkoppling.
Kontrollera luftmotorn och dess tätningar och byt ut om
nödvändigt.
Byt eller rengör filter.
Kontrollera eventuell kondesering i luftfilter eller om pum-
pen har rusat, kontrollera ev. läckage i rörledning.
Se ovan. Kontrollera att centralstången rör sig utan hinder
och att inga partiklar eller föremål finns i kolven.
Kontrollera vätskenivå i förhållande till sugrör.
Kontrollera fjäderns rörelse och att ventilen tätar.
Kontrollera att inget skräp har fastnat i bottenventilen.
Kontrollera skräp i kolvens kulsäte. Kontrollera tätningarna.
Se "Byte av manschettpackning mellan luftmotor och
pumprör"
Se "Service Pumprör"
Se "Service Pumprör"