Stingr Serial Packet Commands; Initiate Proprietary Track" Command - Globalstar STINGR User Manual

Hide thumbs Also See for STINGR:
Table of Contents

Advertisement

5.2.3 STINGR Serial Packet Commands

5.2.3.1 "Initiate proprietary track" command

This command allows the initiation of a periodic track with user defined data prepended and appended to the latitude
and longitude fields. A periodic 9 byte custom track message, transmitted nominally at the interval specified, will result.
Byte
0
1
2
3 -4
5
6
7
8-9
Leader
len
AA
0A
Example Command:
AA 0A 30
Where:
Period :
Payload Byte 0:
Payload Byte 7:
Payload Byte 8:
Revision 0.2
06/24/15
Revision 0.2
Initiate proprietary track command format
Bits
Parameter
0 – 7
Leader
0 – 7
Length
0 – 7
Command Code.
0 - 15
Interval
0 - 7
Byte 0 value
0 - 7
Byte 7 value
0 - 7
Byte 8 value
0 - 15
CRC
Interval
Cmd
(MSB)
30
00
00 05 AA BB CC
69 36
0x0005 (5 minute intervals)
0xAA
0xBB
0xCC
Subject To Change without Notice
STINGR Users Manual
Description
Always a value of 0xAA.
0x0A (decimal 10)
0x30 = Initiate proprietary track.
Interval in minutes between the track points.
MIN and MAX allowed TBD.
The value to transmit as byte 0
The value to transmit as byte 7.
The value to transmit as byte 8.
Interval
(LSB)
Byte 0
Byte 7
05
AA
BB
Byte 8
CRC1
CRC2
CC
18
59
P a g e
| 22

Advertisement

Table of Contents
loading

Table of Contents