Query Setup (0X07) - Globalstar STINGR User Manual

Hide thumbs Also See for STINGR:
Table of Contents

Advertisement

Where:
RF channel :
# of bursts:
Minimum Burst Interval:
Maximum Burst Interval:
Example Command:
AA 0E 06 00 00 00 00
Where the setup information is:
RF channel :
# of bursts:
Minimum Burst Interval:
Maximum Burst Interval:

5.2.2.7 Query Setup (0x07)

The Query Setup command requests the STINGR to return the current setup parameters.
0x07
Leader
AA
Command:
AA 05 07 66 B0
Response:
Leader
len
cmd
AA
0E
07
XX
Where:
RF channel :
# of bursts:
Minimum Burst Interval:
Maximum Burst Interval:
Example Response:
AA 0E 07 00 23 18 60
Revision 0.2
06/24/15
Revision 0.2
Valid values are: 0 = Channel A, 1 = Channel B, 2 = Channel C, 3 = Channel D
Valid values are: 0x01 thru x14 (1 to 20 bursts)
Units of 5 seconds. Valid values are: 0x01 thru 0x3C (5 to 300 seconds)
Units of 5 seconds. Valid values are: 0x02 thru 0x78 (10 to 600 seconds)
00 03 18 30
00
Channel A
03
3 bursts per message
18
0x18 = 24, 24 x 5 = 120 seconds
30
0x30 = 48, 48 x 5 = 240 seconds
len
cmd
CRC1
05
07
66
RF
RESERVED
channel
XX
XX
XX
XX
Valid values are: 0 = Channel A, 1 = Channel B, 2 = Channel C, 3 = Channel D
Valid values are: 0x01 thru x14 (1 to 20 bursts)
Units of 5 seconds. Valid values are: 0x01 thru 0x3C (5 to 300 seconds)
Units of 5 seconds. Valid values are: 0x02 thru 0x78 (10 to 600 seconds)
00 03 18 30
Subject To Change without Notice
STINGR Users Manual
00 CE 9C
CRC2
B0
# of
Interval
Bursts
Min
XX
XX
00 5D 60
Interval
Max
RESERVED
XX
XX
P a g e
| 20
CRC1
CRC2
18
59

Advertisement