Installing the Switch into a 2-Post Rack
Figure 7: Installing Rack-mount Brackets on the Rear Side of the Chassis
c) Repeat Step 1b, for the other front rack-mount bracket on the other side of the switch and be sure to position that
bracket the same distance from the front of the switch.
Note
Install the NEBS air-baffle onto the switch in case of port-side intake. For more information, see
Compliance, on page
Step 2
Install the switch onto the 2-post rack:
a) Holding the switch with both hands, position the back of the switch between the two posts of the rack. Then gently
move the switch until the front rack-mount brackets come in contact with two rack posts.
b) Holding the chassis level, insert two screws (12-24 or 10-32, depending on the rack type) into each of the two front
rack-mount brackets (using a total of four screws) and into the cage nuts or threaded holes in the vertical rack-mounting
posts.
Installing the Cisco MDS 9220i Switch
14