9.1 Hob dimensions
Width
Depth
9.2 Bypass diameters
BURNER
Triple Crown
Semi-rapid
Auxiliary
9.3 Other technical data
TOTAL POWER:
Electric supply:
Appliance category:
Gas connection:
Appliance class:
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER
Triple Crown
Semi-rapid
Auxiliary
Ø BYPASS 1/100 mm
56
32
28
Gas original:
Gas replacement:
230 V ~ 50 Hz
II2H3+
G 1/2"
3
NORMAL POWER kW MINIMUM POWER
4,0
2,0
1,0
B) Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
595 mm
525 mm
G20 (2H) 20 mbar = 9 kW
G30 (3+) 28-30 mbar = 654 g/h
G31 (3+) 37 mbar = 643 g/h
kW
1,4
0,45
0,33
INJECTOR MARK
1/100 mm
146
96
70