581B060 (5 TONS) — STANDARD MOTOR — SINGLE-PHASE UNITS
AIRFLOW
0.1
(Cfm)
Rpm
Bhp
Rpm
1500
771
0.37
1600
816
0.45
1700
902
0.61
1800
942
0.70
1900
982
0.80
2000
1022
0.91
2100
1063
0.99
2200
1104
1.13
2300
1130
1.26
2400
1174
1.37
2500
1201
1.48
581B060 (5 TONS) — STANDARD MOTOR — THREE-PHASE UNITS
AIRFLOW
0.1
(Cfm)
Rpm
Bhp
Rpm
1500
771
0.37
1600
816
0.45
1700
902
0.61
1800
942
0.70
1900
982
0.80
2000
1022
0.91
2100
1063
0.99
2200
1104
1.13
2300
1130
1.26
2400
1174
1.37
2500
1201
1.48
581B060 (5 TONS) — HIGH-STATIC MOTOR
AIRFLOW
0.2
(Cfm)
Rpm
1500
808
1600
846
1700
884
1800
924
1900
965
2000
1008
2100
1051
2200
1095
2300
1140
2400
1185
2500
1231
581B060 (5 TONS) — HIGH-STATIC MOTOR (cont)
AIRFLOW
1.2
(Cfm)
Rpm
1500
1199
1600
1263
1700
1295
1319
1800
1900
1343
2000
1374
2100
1409
2200
1442
2300
1475
2400
1565
2500
1596
L
EGEND
Bhp
— Brake Horsepower Input to Fan
FIOP — Factory-Installed Option
NOTES:
1. Boldface indicates field-supplied drive required. (See Note 3.)
2.
indicates field-supplied motor and drive required.
3. Motor drive range is 1020 to 1460 rpm for single-phase standard motors,
1120 to 1585 for 3-phase standard motors, and 1300 to 1685 for high-static
motors. All other rpms require a field-supplied drive.
4. Values include losses for filters, unit casing, and wet coils. See page 40 for
accessory/FIOP static pressure information.
PERFORMANCE DATA — (cont)
FAN PERFORMANCE — VERTICAL DISCHARGE UNITS (cont)
EXTERNAL STATIC PRESSURE (in. wg)
0.2
0.4
Bhp
Rpm
Bhp
Rpm
828
0.44
935
0.58
1027
869
0.51
968
0.66
1056
940
0.60
1007
0.75
1094
978
0.66
1063
0.82
1147
1023
0.78
1097
0.91
1175
1068
0.90
1132
1.01
1218
1115
1.00
1180
1.17
1261
1159
1.15
1214
1.28
1310
1202
1.29
1248
1.38
1358
1237
1.41
1292
1.55
1392
1272
1.53
1335
1.71
1427
EXTERNAL STATIC PRESSURE (in. wg)
0.2
0.4
Bhp
Rpm
Bhp
Rpm
828
0.44
935
0.58
1027
869
0.51
968
0.66
1056
940
0.60
1007
0.75
1094
978
0.66
1063
0.82
1147
1023
0.78
1097
0.91
1175
1068
0.90
1132
1.01
1218
1115
1.00
1180
1.17
1261
1159
1.15
1214
1.28
1310
1202
1.29
1248
1.38
1358
1237
1.41
1292
1.55
1392
1272
1.53
1335
1.71
1427
0.4
Bhp
Rpm
Bhp
0.42
914
0.56
0.49
950
0.64
0.57
983
0.72
0.66
1018
0.82
0.76
1057
0.92
0.87
1096
1.04
0.99
1136
1.17
1.12
1173
1.30
1.26
1210
1.47
1.41
1249
1.61
1.57
1289
1.78
1.4
Bhp
Rpm
1.19
1126
1275
1.28
1351
1.39
1.52
1389
1.64
1415
1.77
1438
1.91
1465
2.08
1498
2.26
1554
2.47
1649
2.95
1682
0.6
0.8
Bhp
Rpm
Bhp
Rpm
0.73
1107
0.88
1185
0.81
1127
0.97
1215
0.91
1175
1.09
1245
0.97
1248
1.20
1322
1.11
1266
1.29
1356
1.23
1303
1.41
1397
1.35
1340
1.53
1428
1.52
1375
1.63
1459
1.69
1410
1.72
1488
1.81
1460
1.90
1532
1.94
1518
2.16
1575
0.6
0.8
Bhp
Rpm
Bhp
Rpm
0.73
1107
0.88
1185
0.81
1127
0.97
1215
0.91
1175
1.09
1245
0.97
1248
1.20
1322
1.11
1266
1.29
1356
1.23
1303
1.41
1397
1.35
1340
1.53
1428
1.52
1375
1.63
1459
1.69
1410
1.72
1488
1.81
1460
1.90
1532
1.94
1518
2.16
1575
EXTERNAL STATIC PRESSURE (in. wg)
0.6
Rpm
Bhp
1001
0.69
1034
0.78
1068
0.88
1105
0.98
1143
1.10
1177
1.22
1210
1.35
1245
1.49
1284
1.65
1323
1.80
1363
2.00
EXTERNAL STATIC PRESSURE (in. wg)
1.6
Bhp
Rpm
Bhp
1.46
1250
1.69
1.49
1299
1.78
1.58
1352
1.80
1.71
1435
1.91
1.80
1478
2.05
1.99
1505
2.21
2.14
1533
2.45
2.30
1568
2.64
2.64
1627
3.03
2.89
1726
3.31
3.45
1760
3.96
5. Maximum continuous bhp is 1.30 for single-phase standard motors, 2.40 for
3-phase standard motors, and 2.90 for high-static motors. Extensive motor
and electrical testing on these units ensures that the full range of the motor
can be utilized with confidence. Using your fan motors up to the ratings
shown will not result in nuisance tripping or premature motor failure. Unit
warranty will not be affected. See Evaporator-Fan Motor Data tables on
pages 41 and 42 for additional information.
6. Use of a field-supplied motor may affect wire sizing. Contact your Bryant
representative to verify.
7. Interpolation is permissible. Do not extrapolate.
28
1.0
1.2
1.4
Bhp
Rpm
Bhp
Rpm
1.04
1257
1.20
1330
1.14
1286
1.31
1353
1.26
1315
1.44
1381
1.33
1395
1.46
1475
1.47
1430
1.58
1504
1.52
1459
1.67
1532
1.66
1489
1.80
1567
1.80
1528
1.95
1603
1.93
1561
2.13
1637
2.14
1584
2.28
1671
2.35
1633
2.53
1698
1.0
1.2
1.4
Bhp
Rpm
Bhp
Rpm
1.04
1257
1.20
1330
1.14
1286
1.31
1353
1.26
1315
1.44
1381
1.33
1395
1.46
1475
1.47
1430
1.58
1504
1.52
1459
1.67
1532
1.66
1489
1.80
1567
1.80
1528
1.95
1603
1.93
1561
2.13
1637
2.14
1584
2.28
1671
2.35
1633
2.53
1698
0.8
Rpm
Bhp
1084
0.85
1111
0.94
1145
1.03
1179
1.13
1212
1.26
1247
1.40
1284
1.54
1322
1.70
1356
1.80
1389
2.03
1424
2.22
1.8
Rpm
Bhp
1301
1.91
1352
2.01
1407
2.03
1494
2.15
1538
2.31
1566
2.49
1596
2.77
1632
2.97
1693
3.42
1.6
Bhp
Rpm
Bhp
1.38
1411
1.59
1.49
1421
1.68
1.52
1443
1.69
1.56
1542
1.71
1.69
1556
1.82
1.82
1588
1.97
1.99
1626
2.16
2.17
1666
2.37
2.35
1710
2.54
2.55
1756
2.70
2.72
1.6
Bhp
Rpm
Bhp
1.38
1411
1.59
1.49
1421
1.68
1.52
1443
1.69
1.56
1542
1.71
1.69
1556
1.82
1.82
1588
1.97
1.99
1626
2.16
2.17
1666
2.37
2.35
1710
2.54
2.55
1756
2.70
2.72
1.0
Rpm
Bhp
1168
1.01
1194
1.11
1218
1.21
1246
1.32
1280
1.43
1300
1.57
1347
1.72
1380
1.89
1418
2.07
1456
2.26
1500
2.45
2.0
Rpm
Bhp
1349
2.12
1401
2.23
1459
2.26
1548
2.40
1594
2.57
1624
2.77
1654
3.08
1691
3.31
1755
3.81