D30061
Other commands
"S" status
This command provides an overview of the status of the 4430 unit. The 4430 unit
sends the status data as a text message to the phone of the person sending the
enquiry.
An example of the data received in response to the "1234 S4" command:
Response text message:
Wallas: Heater is off.
Local control.
switch.
Set temp:16C
Read temp:25C
Volt:12.0V
GSM12A+ V3.4
Connections for a Wallas heater
TXU
Data to Wallas
RXI
Data from Wallas
GND
Wallas Data grounding
T1
Temperature signal input
T2
Temperature signal 2 input
GND
Normal grounding
I1
Input 1
I2
Input 2
S
Signal
GND
Grounding
+12V
Output 7 – 15 VDC
GND
Grounding
R1
Relay 1
R1
Relay 1
R2
Relay 2
R2
Relay 2
4430 takes power from the Wallas heater's control panel
Frequently Asked Questions
No signal LED:
•
Check whether the power source is connected correctly
•
Check the accumulator charge
•
Check the signal
•
Check the aerial connection
The green LED flashes with short intervals:
•
Check whether the Mini-SIM card is in place
•
Check if the PIN code has been disabled
•
Check whether the SIM card is valid
The LED colour is red:
•
Wait for 2 – 3 seconds for the unit to automatically restart.
If it stays on, try to restart the 4430 unit by disconnecting the power source for
•
10 seconds.
•
Please contact the equipment dealer.
4430A
Operation
The heater has been stopped
The heater has been adjusted with the equipment control
The user-set temperature is 16°C
The measured temperature of the room is 25°C
The voltage is 12.0 V
Remote starter's software version
- 45 -
10 pin connector
10 pin connector
10 pin connector
10 pin connector
10 pin connector
10 pin connector
10 pin connector
10 pin connector
10 pin connector
10 pin connector
6 pin connector
6 pin connector
6 pin connector
6 pin connector
6 pin connector
6 pin connector
en
490538A