17.3 TIME JAM TIME OUT

An error message will appear when the conditions for a requested Time Jam are not met.
1. Menu 1.1: Reference must be Input A or Input B.
2. Menu 1.2: A valid source must be selected as the BNC INPUT TIME JAM SOURCE.
3. Menu 5.1: If PTP was selected, TIME JAM (BNC INPUT) will automatically show in menu
5.1, in blue (blue = status information). The words [Time Jam] will also appear on the
REFERENCE line at the bottom of the main rotation pages.
4. Menu 5.5: If PTP was selected, the PTP domain of the Time Jam must be set to the same
domain as the external PTP Grandmaster source in menu 5.5.
-
Make sure the menus listed above are set properly.
DXD/PTP/GPS User Manual (rev 2.10)
ERROR
BNC Input Time Jam has
TIMED OUT
Press Any Key to Clear